C5H3V36*K*AAA*
ProComfort 23 VS HP · source records, page 3
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 541 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.14 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X42M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215936171 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3728234 → |
EVD5X42M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215936181 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3728244 → |
EVD5X42M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215936191 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3728254 → |
EVM5X44M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215940271 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3728374 → |
EVM5X44M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215940281 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3728384 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0401712A*Cold climate designationAHRI reference: 215934981 | 22.00 | 8.50 | 28800 | 2.02 | EPA 3729723 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215940341 | 22.00 | 8.50 | 28600 | 2.04 | EPA 3729774 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215940351 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3729784 → |
EVM5X49M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215940391 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3729824 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215936621 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3729910 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215936631 | 22.00 | 8.50 | 28400 | 2.02 | EPA 3729920 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215936641 | 22.00 | 8.50 | 28400 | 2.02 | EPA 3729930 → |
EVD5X42M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215936251 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3730081 → |
EVD5X42M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215936261 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3730092 → |
EVD5X42M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215936271 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3730101 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215936671 | 22.00 | 9.00 | 28400 | 2.14 | EPA 3730390 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215935031 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3731591 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215935041 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3731601 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215935051 | 22.00 | 8.50 | 28400 | 2.02 | EPA 3731611 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215940411 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3731651 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →