Keeprite / AIR-SOURCE HEAT PUMP

C5H0V60*K*AAA*

ProComfort 20 VS HP · source records, page 7

158 published source records · source checked Sep 21, 2026

SEER2 range16.5–19BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for C5H0V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 158 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.5–19158 / 158
EER2 · BTU/Wh8–9.8158 / 158
HSPF2 · BTU/Wh8.1–9158 / 158
Cooling capacity · BTU/h54,000–58,000158 / 158
Heating capacity at 47°F / 8.3°C · BTU/h59,000–63,50054 / 158
Heating capacity at 17°F / −8.3°C · BTU/h50,500–57,500158 / 158
Heating capacity at 5°F / −15°C · BTU/h41,000–46,000158 / 158
COP at 5°F / −15°C1.86–2.1158 / 158
Equipment / loop typeHP - Split System158 / 158
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)158 / 158
Compressor stagingContinuously variable158 / 158
Connected capabilityNo158 / 158

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568260018.008.50415002.02EPA 3977550
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568268018.008.50415002.02EPA 3977945
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21568299018.009.00450002.08EPA 3978117
EVD5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568303018.009.00445002.08EPA 3978145
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21568304018.009.00450002.08EPA 3978148
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21568280018.009.00450002.06EPA 3978165
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568284018.009.00445002.08EPA 3978195
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21568285018.009.00450002.06EPA 3978205
EVD5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21568306018.009.00445002.08EPA 3978235
EVD5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21568307018.009.00440002.10EPA 3978252
EVD5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568308018.009.00440002.08EPA 3978265
EVD5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21568309018.009.00445002.08EPA 3978271
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21568287018.009.00445002.08EPA 3978296
EVM5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21568288018.009.00440002.10EPA 3978307
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568289018.009.00445002.08EPA 3978323
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21568290018.009.00445002.08EPA 3978333
EVM5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568295018.009.00445002.10EPA 3978385
EVD5X61M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568316018.009.00445002.08EPA 3978479
EVD5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21568321018.009.00445002.10EPA 3978526
EVM5X60M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21567717017.508.50455001.94EPA 3971269

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →