| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X48M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215674947 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968428 → |
ESH5X48M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215675108 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968518 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215675127 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968682 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215675150 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968712 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215675190 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968738 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215675200 | 16.50 | 8.50 | 34000 | 2.06 | EPA 3968746 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675210 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968754 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675220 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968767 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215675230 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968778 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215675250 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968802 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675260 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968872 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215675290 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968905 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215675300 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968914 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215675310 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968920 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215675330 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968931 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215675340 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3969009 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681590 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3975298 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681670 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3975397 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681680 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3975412 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681710 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3975438 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →