| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 215675350 | 19.50 | 9.50 | 33000 | 2.20 | EPA 3969027 → |
EVM5X61M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675960 | 19.50 | 9.00 | 36600 | 2.10 | EPA 3969469 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675990 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969500 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215676000 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969516 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215676010 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969520 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676060 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970015 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215676070 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970023 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676080 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970034 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215676090 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970055 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215676750 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970422 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215676760 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970433 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676820 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970573 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676840 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970599 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215676850 | 19.50 | 9.00 | 36600 | 2.10 | EPA 3970606 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215676880 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3970800 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215676890 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3970810 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676930 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971342 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215676940 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971345 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676950 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971365 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215676960 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3971371 → |