Keeprite / AIR-SOURCE HEAT PUMP

B5H6S18*K*AAA*

MAINLINE 16 SEER2 HP

44 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for B5H6S18*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 44 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.544 / 44
EER2 · BTU/Wh11.7–12.544 / 44
HSPF2 · BTU/Wh7.8–844 / 44
Cooling capacity · BTU/h17,400–18,90044 / 44
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,10044 / 44
Heating capacity at 17°F / −8.3°C · BTU/h10,500–10,90044 / 44
Heating capacity at 5°F / −15°C · BTU/h8,200–8,50044 / 44
COP at 5°F / −15°C1.94–2.144 / 44
Equipment / loop typeHP - Split System44 / 44
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)44 / 44
Compressor stagingSingle stage44 / 44
Connected capabilityNo44 / 44

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X24**AL*AHRI reference: 21821639615.508.0082002.10EPA 4584630
EVM5X32M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21821581315.507.8082001.94EPA 4584639
EVM5X32M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21821581015.507.8082001.94EPA 4584642
F5MA5*30L*B*AHRI reference: 21821651015.207.8084002.02EPA 4584618
FM(C,U)5Z30**AL*AHRI reference: 21821650115.207.8082001.96EPA 4584621
FM(C,U)5Z24**AL*AHRI reference: 21821649815.208.0085002.04EPA 4584624
FM(C,U)5Z18**AL*AHRI reference: 21821649515.208.0085002.04EPA 4584627
FMA5X18**AL*AHRI reference: 21821639315.207.8082002.00EPA 4584633
FHMA5*30L*B*AHRI reference: 21821609815.207.8084002.02EPA 4584636
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21821561515.207.8084002.04EPA 4584645
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21821560915.207.8084002.04EPA 4584648
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21821560315.207.8085002.04EPA 4584651
EA*5X25M17A*+ furnace: *96MSN0801716A*AHRI reference: 21821559415.207.8085002.04EPA 4584654
EA*5X25M17A*+ furnace: *92MSN0801716A*AHRI reference: 21821559115.207.8084002.06EPA 4584657
EA*5X25M17A*+ furnace: *92MSN0601714A*AHRI reference: 21821558815.207.8084002.04EPA 4584660
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21821557315.207.8085002.04EPA 4584663
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21821557015.207.8084002.04EPA 4584666
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21821556715.207.8085002.04EPA 4584669
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21821556415.207.8085002.04EPA 4584672
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 21821556115.207.8084002.06EPA 4584675

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →