B5H3V36*K*AAA*
ProComfort 23 VS HP · source records, page 6
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X61M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218416462 | 22.00 | 8.50 | 28200 | 2.08 | EPA 4608079 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218416446 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608095 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218416438 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4608103 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218416430 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4608111 → |
EVM5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218416406 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608135 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218416398 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608143 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218416390 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608151 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218416382 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608159 → |
FCMA5B48L0C*+WALLCONCold climate designationAHRI reference: 218405877 | 21.50 | 9.50 | 25800 | 2.06 | EPA 4601653 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218411765 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603729 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218411741 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603753 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218411717 | 21.50 | 8.50 | 28400 | 2.06 | EPA 4603777 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218411693 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603801 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218411661 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603833 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218411645 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603849 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218411613 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603881 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218411605 | 21.50 | 8.50 | 28800 | 2.04 | EPA 4603889 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218411589 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603905 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218411581 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4603913 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218411557 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603937 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →