Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X42M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218412213 | 21.00 | 8.50 | 28200 | 2.06 | EPA 4607281 → |
EVD5X42M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218412189 | 21.00 | 8.50 | 28000 | 2.06 | EPA 4607305 → |
EVD5X42M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218412181 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607313 → |
EVD5X38M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218412149 | 21.00 | 8.50 | 29200 | 2.08 | EPA 4607337 → |
EVD5X38M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218412125 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607361 → |
EVD5X38M17A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218412117 | 21.00 | 8.50 | 29200 | 2.04 | EPA 4607369 → |
EVD5X38M17A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218412109 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607377 → |
EVD5X38M17A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218412101 | 21.00 | 8.50 | 29200 | 2.06 | EPA 4607385 → |
EVD5X38M17A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218412069 | 21.00 | 8.50 | 29600 | 2.04 | EPA 4607417 → |
EVD5X36M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218412029 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607457 → |
EVD5X36M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218411997 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607489 → |
EVD5X36M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218411965 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607521 → |
EVD5X36M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218411925 | 21.00 | 8.50 | 28000 | 2.06 | EPA 4607561 → |
EVD5X36M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218411901 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607585 → |
EVD5X36M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218411893 | 21.00 | 8.50 | 28000 | 2.06 | EPA 4607593 → |
EVD5X36M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218411885 | 21.00 | 8.50 | 28200 | 2.06 | EPA 4607601 → |
EVD5X36M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218411877 | 21.00 | 8.50 | 28200 | 2.06 | EPA 4607609 → |
EVD5X36M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218411853 | 21.00 | 8.50 | 28000 | 2.06 | EPA 4607633 → |
EVM5X44M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218416342 | 21.00 | 8.50 | 28000 | 2.06 | EPA 4607983 → |
EVM5X44M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218416334 | 21.00 | 8.50 | 28000 | 2.08 | EPA 4607991 → |