B5H0V60*K*AAA*
ProComfort 20 VS HP · source records, page 3
96 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 96 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–20 | 96 / 96 |
| EER2 · BTU/Wh | 8–10 | 96 / 96 |
| HSPF2 · BTU/Wh | 8.5–9 | 96 / 96 |
| Cooling capacity · BTU/h | 54,000–57,500 | 96 / 96 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 57,500–65,000 | 96 / 96 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,000–57,500 | 96 / 96 |
| Heating capacity at 5°F / −15°C · BTU/h | 40,500–46,000 | 96 / 96 |
| COP at 5°F / −15°C | 1.86–2.12 | 96 / 96 |
| Equipment / loop type | HP - Split System | 96 / 96 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 96 / 96 |
| Compressor staging | Continuously variable | 96 / 96 |
| Connected capability | No | 96 / 96 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218167513 | 18.50 | 9.00 | 44500 | 2.08 | EPA 4596969 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218167510 | 18.50 | 9.00 | 44500 | 2.08 | EPA 4596972 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218167486 | 18.50 | 9.00 | 45000 | 2.08 | EPA 4596996 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218167483 | 18.50 | 9.00 | 45000 | 2.08 | EPA 4596999 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218167468 | 18.50 | 9.00 | 44500 | 2.08 | EPA 4597014 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218167465 | 18.50 | 9.00 | 44500 | 2.08 | EPA 4597017 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218167924 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4596603 → |
EVD5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218167918 | 18.00 | 9.00 | 44000 | 2.10 | EPA 4596609 → |
EVD5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218167915 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4596612 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218167909 | 18.00 | 9.00 | 45000 | 2.08 | EPA 4596618 → |
EVD5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218167906 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4596621 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218167894 | 18.00 | 9.00 | 45000 | 2.08 | EPA 4596630 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218167867 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4596654 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218167864 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4596657 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218167861 | 18.00 | 9.00 | 44000 | 2.10 | EPA 4596660 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218167858 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4596663 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218167852 | 18.00 | 9.00 | 45000 | 2.06 | EPA 4596669 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218167849 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4596672 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218167837 | 18.00 | 9.00 | 45000 | 2.06 | EPA 4596681 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218167777 | 18.00 | 8.50 | 41500 | 2.02 | EPA 4596726 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →