275 published source records · source checked Sep 21, 2026

SEER2 range16–19.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,800–35,400BTU/h

Each efficiency range summarizes published EPA records for B5H0V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19.5275 / 275
EER2 · BTU/Wh9–11.5275 / 275
HSPF2 · BTU/Wh8.1–9.5275 / 275
Cooling capacity · BTU/h32,800–35,400275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,000275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h29,400–31,800275 / 275
Heating capacity at 5°F / −15°C · BTU/h23,600–25,800275 / 275
COP at 5°F / −15°C1.64–2.04275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingContinuously variable275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 21817123619.509.50244002.04EPA 4589743
FCMA5B48L0C*+WALLCONCold climate designationAHRI reference: 21817059819.009.00246001.96EPA 4589434
EVD5X61M24A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21817216919.008.50236001.64EPA 4705526
EVD5X61M24A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21817216619.008.50236001.64EPA 4705529
EVD5X61M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21817216319.008.50236001.64EPA 4705532
EVM5X61M24A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21817160219.008.50236001.64EPA 4705547
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21817159919.008.50236001.64EPA 4705550
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21817159619.008.50236001.64EPA 4705560
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21817234618.509.00248001.92EPA 4580736
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21817234318.509.00248001.92EPA 4580739
EA*5X61M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21817233418.509.00248001.92EPA 4580748
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21817231318.509.00248001.90EPA 4580769
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21817231018.509.00248001.90EPA 4580772
FCMA5B36L0C*+WALLCONCold climate designationAHRI reference: 21817123318.509.00256001.86EPA 4589746
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21817097318.509.00248001.92EPA 4590001
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21817097018.509.00248001.92EPA 4590004
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21817096718.509.00248001.92EPA 4590007
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21817096418.509.00248001.92EPA 4590010
EA*5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21817095518.509.00246001.92EPA 4590019
EA*5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21817094918.509.00246001.92EPA 4590025

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.