3KARDA12SZO
3KAR series · KARDA
9 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 3KARDA12SZO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 9 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19.5–24.2 | 9 / 9 |
| EER2 · BTU/Wh | 11.7–13.5 | 9 / 9 |
| HSPF2 · BTU/Wh | 9.5–10.7 | 9 / 9 |
| Cooling capacity · BTU/h | 12,000 | 9 / 9 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 12,000–12,500 | 9 / 9 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 7,500–10,600 | 9 / 9 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,000–12,100 | 9 / 9 |
| COP at 5°F / −15°C | 1.8–1.99 | 9 / 9 |
| Equipment / loop type | HP - Mini or Multi Split | 9 / 9 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 9 / 9 |
| Compressor staging | Continuously variable | 9 / 9 |
| Connected capability | No | 9 / 9 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
3KARDA12CON-2Cold climate designationAHRI reference: 210410112 | 24.20 | 10.70 | 11900 | 1.99 | EPA 2448442 → |
3KARDA12CONCold climate designationAHRI reference: 207796640 | 23.60 | 10.00 | 12000 | 1.89 | EPA 2450039 → |
1KARDA12UVWCold climate designationAHRI reference: 207614052 | 23.60 | 9.50 | 10000 | 1.80 | EPA 2450197 → |
2KARDA12UVCSCold climate designationAHRI reference: 213785826 | 23.60 | 10.00 | 12000 | 1.89 | EPA 2856428 → |
3KARDA12UVWCold climate designationAHRI reference: 207430432 | 23.10 | 10.50 | 11000 | 1.88 | EPA 2449885 → |
3KARDA12UVCCold climate designationAHRI reference: 207796638 | 22.30 | 10.20 | 11300 | 1.89 | EPA 2449026 → |
2KARDA12UVCCold climate designationAHRI reference: 213785827 | 22.30 | 10.20 | 11300 | 1.89 | EPA 2856429 → |
3KARDA12UVDCold climate designationAHRI reference: 207796639 | 19.50 | 10.00 | 12100 | 1.96 | EPA 2449024 → |
3KARDA12UVDCold climate designationAHRI reference: 207796639 | 19.50 | 10.00 | 12100 | 1.96 | EPA 3996063 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →