Innovair / AIR-SOURCE HEAT PUMP

QOS09H2BH0A

Q4+

5 published source records · source checked Sep 21, 2026

SEER2 range19.5–22BTU/Wh
HSPF2 range9.5–10.5BTU/Wh
Cooling capacity9,000BTU/h

Each efficiency range summarizes published EPA records for QOS09H2BH0A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 5 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19.5–225 / 5
EER2 · BTU/Wh11.7–125 / 5
HSPF2 · BTU/Wh9.5–10.55 / 5
Cooling capacity · BTU/h9,0005 / 5
Heating capacity at 47°F / 8.3°C · BTU/h9,0005 / 5
Heating capacity at 17°F / −8.3°C · BTU/h6,700–8,9005 / 5
Heating capacity at 5°F / −15°C · BTU/h9,000–12,0005 / 5
COP at 5°F / −15°C1.85 / 5
Equipment / loop typeHP - Mini or Multi Split5 / 5
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)5 / 5
Compressor stagingContinuously variable5 / 5
Connected capabilityNo5 / 5

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
QHW09H2UZRACold climate designationAHRI reference: 21677895122.0010.50100001.80EPA 3995768
QHW12H2UZRACold climate designationAHRI reference: 21679006222.0010.50100001.80EPA 3995807
QHW09H2UZRBCold climate designationAHRI reference: 21837327122.009.5090001.80EPA 4593526
QCS09H2BHRACold climate designationAHRI reference: 21662616020.009.50120001.80EPA 3893626
QDL09H2BHWACold climate designationAHRI reference: 21662615819.509.50120001.80EPA 3893624

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →