Innovair / AIR-SOURCE HEAT PUMP

MOS18H2BH0A

MDH Series · MDL Series · MHW Series · MOS Series

8 published source records · source checked Sep 21, 2026

SEER2 range18–21.4BTU/Wh
HSPF2 range10–12.3BTU/Wh
Cooling capacity16,000–18,000BTU/h

Each efficiency range summarizes published EPA records for MOS18H2BH0A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 8 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–21.48 / 8
EER2 · BTU/Wh12–12.58 / 8
HSPF2 · BTU/Wh10–12.38 / 8
Cooling capacity · BTU/h16,000–18,0008 / 8
Heating capacity at 47°F / 8.3°C · BTU/h17,000–20,0008 / 8
Heating capacity at 17°F / −8.3°C · BTU/h14,000–18,0008 / 8
Heating capacity at 5°F / −15°C · BTU/h17,000–18,0008 / 8
COP at 5°F / −15°C1.86–2.28 / 8
Equipment / loop typeHP - Mini or Multi Split · HP - Split System8 / 8
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)8 / 8
Compressor stagingContinuously variable8 / 8
Connected capabilityNo8 / 8

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MHW18H2BHRBCold climate designationAHRI reference: 21572544521.4011.00180001.92EPA 3629949
MCO18H2BHRACold climate designationAHRI reference: 21723002120.6012.20175001.89EPA 4015759
MFC18H2BHRACold climate designationAHRI reference: 21723001320.4010.30170001.86EPA 4015751
MCS18H2BHRACold climate designationAHRI reference: 21723000020.0012.30170001.90EPA 4015740
MCW16H2BHRACold climate designationAHRI reference: 21723000720.0010.30175001.95EPA 4015747
MDH18H2MHWACold climate designationAHRI reference: 21572547218.4011.10180002.10EPA 3629972
MDL18H2MHWACold climate designationAHRI reference: 21572546918.0010.50180002.00EPA 3629968
MAH18H2MHWACold climate designationAHRI reference: 21867984518.0010.00180002.20EPA 4670027

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →