Heil / AIR-SOURCE HEAT PUMP

R5H5S31*K*AAA*

15 SEER2 HP · source records, page 2

39 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for R5H5S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 39 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1639 / 39
EER2 · BTU/Wh11.7–1339 / 39
HSPF2 · BTU/Wh7.8–839 / 39
Cooling capacity · BTU/h27,400–29,40039 / 39
Heating capacity at 47°F / 8.3°C · BTU/h29,400–30,60039 / 39
Heating capacity at 17°F / −8.3°C · BTU/h17,500–18,20039 / 39
Heating capacity at 5°F / −15°C · BTU/h13,400–14,00039 / 39
COP at 5°F / −15°C2–2.0639 / 39
Equipment / loop typeHP - Split System39 / 39
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)39 / 39
Compressor stagingSingle stage39 / 39
Connected capabilityNo39 / 39

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+ furnace: *80CSU0802120B*AHRI reference: 21769184615.508.00139002.04EPA 4507026
EA*5X43M21A*+ furnace: *92MSN0802120A*AHRI reference: 21769272315.508.00140002.06EPA 4507051
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 21769274615.508.00140002.06EPA 4507074
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21769027215.508.00140002.06EPA 4507108
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21769034515.508.00140002.04EPA 4507146
EA*5X43M21A*+ furnace: *92MSN1002122A*AHRI reference: 21769277015.508.00140002.06EPA 4507183
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21769117515.508.00140002.06EPA 4507193
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21769206815.508.00140002.04EPA 4507220
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21769204315.508.00140002.06EPA 4507228
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21769032015.508.00140002.06EPA 4507254
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 21769215215.508.00140002.06EPA 4507269
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 21769220215.508.00140002.06EPA 4507285
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 21769222915.508.00140002.06EPA 4507319
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 21769338515.508.00140002.06EPA 4507338
FEVA0036**+NAVA53601CKAHRI reference: 21770216315.507.80134002.00EPA 4508700
FEVB0036**+NAVA53601CKAHRI reference: 21770219015.507.80134002.00EPA 4508851
FM(C,U)5S36**AL*AHRI reference: 21845249615.508.00135002.00EPA 4624313
FM(C,U)5S30**AL*AHRI reference: 21845247715.508.00135002.00EPA 4624332
FMA5L30**AL*AHRI reference: 21768353815.208.00138002.00EPA 4506149

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →