R5H5S31*K*AAA*
15 SEER2 HP · source records, page 2
39 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 39 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 39 / 39 |
| EER2 · BTU/Wh | 11.7–13 | 39 / 39 |
| HSPF2 · BTU/Wh | 7.8–8 | 39 / 39 |
| Cooling capacity · BTU/h | 27,400–29,400 | 39 / 39 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 39 / 39 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,200 | 39 / 39 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 39 / 39 |
| COP at 5°F / −15°C | 2–2.06 | 39 / 39 |
| Equipment / loop type | HP - Split System | 39 / 39 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 39 / 39 |
| Compressor staging | Single stage | 39 / 39 |
| Connected capability | No | 39 / 39 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+ furnace: *80CSU0802120B*AHRI reference: 217691846 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4507026 → |
EA*5X43M21A*+ furnace: *92MSN0802120A*AHRI reference: 217692723 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507051 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 217692746 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507074 → |
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 217690272 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507108 → |
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 217690345 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4507146 → |
EA*5X43M21A*+ furnace: *92MSN1002122A*AHRI reference: 217692770 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507183 → |
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 217691175 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507193 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 217692068 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4507220 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 217692043 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507228 → |
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 217690320 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507254 → |
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 217692152 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507269 → |
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 217692202 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507285 → |
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 217692229 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507319 → |
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 217693385 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507338 → |
FEVA0036**+NAVA53601CKAHRI reference: 217702163 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4508700 → |
FEVB0036**+NAVA53601CKAHRI reference: 217702190 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4508851 → |
FM(C,U)5S36**AL*AHRI reference: 218452496 | 15.50 | 8.00 | 13500 | 2.00 | EPA 4624313 → |
FM(C,U)5S30**AL*AHRI reference: 218452477 | 15.50 | 8.00 | 13500 | 2.00 | EPA 4624332 → |
FMA5L30**AL*AHRI reference: 217683538 | 15.20 | 8.00 | 13800 | 2.00 | EPA 4506149 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →