Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 25
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M21A*+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 217952871 | 15.20 | 9.00 | 37600 | 2.08 | EPA 4558975 → |
EA*5X61M21A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217952899 | 15.20 | 9.00 | 37600 | 2.08 | EPA 4559217 → |
ESH5X48M12A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217953081 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4560415 → |
ESH5X48M12A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217953095 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4560431 → |
ESH5X48M12A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 217953109 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4560467 → |
ESH5X48M12A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217953123 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4560481 → |
ESH5X48M12A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217953025 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4561640 → |
ESH5X48M12A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217953039 | 15.20 | 8.50 | 37000 | 1.98 | EPA 4561654 → |
ESH5X48M12A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217953053 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4561708 → |
ESH5X48M12A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217953067 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4561721 → |
ESH5X60M12A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217953250 | 15.20 | 8.50 | 37000 | 2.00 | EPA 4561805 → |
ESH5X60M12A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217953264 | 15.20 | 8.50 | 37200 | 1.95 | EPA 4561819 → |
ESH5X60M12A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217953278 | 15.20 | 9.00 | 37000 | 2.08 | EPA 4561834 → |
ESH5X60M12A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217953292 | 15.20 | 8.50 | 37200 | 1.95 | EPA 4561847 → |
EVD5X60M24A*+TDRCold climate designationAHRI reference: 217954600 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4562115 → |
EA*5X48M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217952688 | 15.20 | 9.00 | 37400 | 2.10 | EPA 4562825 → |
EVM5X60M21A*+TDRCold climate designationAHRI reference: 217954502 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4563514 → |
EVM5X60M24A*+TDRCold climate designationAHRI reference: 217954516 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4563528 → |
EVD5X48M21A*+TDRCold climate designationAHRI reference: 217954544 | 15.20 | 9.00 | 39000 | 2.10 | EPA 4563544 → |
EVD5X60M21A*+TDRCold climate designationAHRI reference: 217954586 | 15.20 | 9.00 | 39500 | 2.10 | EPA 4563567 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →