Heil / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 6

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21793247316.009.00410002.14EPA 4546448 →
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21793248816.009.00405002.14EPA 4546463 →
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21793250316.009.00405002.12EPA 4546478 →
EA*5X61M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21793295416.009.00410002.14EPA 4546605 →
EA*5X61M24A*+ furnace: *97VTN1002122A*AHRI reference: 21793296916.009.00405002.14EPA 4546620 →
EA*5X61M24A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 21793298416.009.00410002.14EPA 4546635 →
EA*5X60M24A*+ furnace: *97CMN1002122B*AHRI reference: 21793169316.009.00405002.12EPA 4546647 →
EA*5X61M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21793230816.008.50410002.00EPA 4547219 →
EA*5X61M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21793233816.008.50410002.00EPA 4547264 →
EA*5X61M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21793236816.009.00410002.14EPA 4547316 →
EA*5X61M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21793238316.009.00410002.14EPA 4547331 →
EA*5X61M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21793241316.009.00410002.14EPA 4547417 →
EA*5X61M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21793242816.009.00410002.14EPA 4547431 →
EA*5X61M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21795342316.008.50410002.00EPA 4557883 →
EA*5X60M24A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21795337516.009.00410002.12EPA 4563117 →
EA*5X61M21A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21795340716.008.50410002.00EPA 4563149 →
EVM5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21791861415.508.00395001.94EPA 4536478 →
EVD5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21792108315.508.00400001.96EPA 4536686 →
EVM5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 21791969815.508.00410001.96EPA 4536973 →
EVM5X60M21A*+ furnace: *97VTN0802120A*AHRI reference: 21791891515.508.00395001.96EPA 4537004 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →