N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 11
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217917276 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4538316 → |
EVD5X60M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217917289 | 16.00 | 9.00 | 41000 | 2.10 | EPA 4538328 → |
EVD5X60M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217917302 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4538341 → |
EVD5X60M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217917350 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4538506 → |
EVD5X48M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217916519 | 16.00 | 9.50 | 40000 | 2.22 | EPA 4538534 → |
EVD5X48M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217916545 | 16.00 | 9.50 | 40000 | 2.22 | EPA 4538602 → |
EVD5X48M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217916585 | 16.00 | 9.50 | 39500 | 2.22 | EPA 4538950 → |
EVD5X60M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217917159 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4539143 → |
EVD5X60M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217917172 | 16.00 | 9.00 | 41000 | 2.10 | EPA 4539158 → |
EVD5X60M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217917185 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4539170 → |
EVD5X60M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217917198 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4539184 → |
EVD5X48M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217916624 | 16.00 | 9.50 | 39500 | 2.22 | EPA 4539378 → |
EVD5X60M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217917250 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4539708 → |
EVD5X61M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217917858 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4540026 → |
EVD5X61M24A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217918015 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4540123 → |
EVD5X61M24A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217918002 | 16.00 | 9.00 | 41000 | 2.12 | EPA 4540146 → |
EVD5X61M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217918041 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4540234 → |
EVD5X61M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217917480 | 16.00 | 9.00 | 41000 | 2.12 | EPA 4540614 → |
EVD5X61M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217917884 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4540955 → |
EVD5X61M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217918080 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4541040 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →