| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X42M21A*+ furnace: *80VSL0902120B*AHRI reference: 217913581 | 15.20 | 8.00 | 26200 | 2.08 | EPA 4530892 → |
EVM5X36M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217908923 | 15.20 | 8.50 | 25800 | 2.02 | EPA 4530963 → |
EVM5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217908953 | 15.20 | 8.50 | 25600 | 2.02 | EPA 4530991 → |
EVD5X36M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217911387 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4531102 → |
EVD5X38M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217912960 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531164 → |
EVD5X38M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217912975 | 15.20 | 8.50 | 26200 | 2.00 | EPA 4531176 → |
EVD5X38M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217913006 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531202 → |
EVM5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217910538 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531345 → |
EVM5X36M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217909028 | 15.20 | 8.50 | 25800 | 2.04 | EPA 4531401 → |
EVD5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217914200 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531510 → |
EVD5X48M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217914350 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4531549 → |
EVD5X36M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217912097 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531676 → |
EVD5X36M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217912113 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531692 → |
EVD5X48M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217914305 | 15.20 | 8.50 | 26400 | 2.00 | EPA 4531757 → |
EVD5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217914320 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531773 → |
EVD5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217912643 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531842 → |
EVD5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217912658 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531855 → |
EVD5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217912567 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531864 → |
EVD5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217912583 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531881 → |
EVM5X48M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217910553 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4532135 → |