Heil / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 2

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 21562550417.508.50248002.28EPA 3949840 →
EVD5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21562575217.508.50248002.26EPA 3950146 →
EVM5X60M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572209617.508.00244002.14EPA 3981733 →
EVD5X60M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572229917.508.00244002.14EPA 3982504 →
EVD5X61M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572231217.508.00248002.26EPA 3982520 →
EVD5X61M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572240217.508.50246002.28EPA 3982612 →
EVD5X61M24A*+ furnace: *80CSU0802120B*AHRI reference: 21572241517.508.00246002.28EPA 3982621 →
EVD5X61M24A*+ furnace: *97VTN1002122A*AHRI reference: 21572251917.508.50248002.26EPA 3982725 →
QFVA5D4821X*AHRI reference: 21869542917.508.10254002.18EPA 4683398 →
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562295917.008.10240002.14EPA 3947364 →
EVM5X49M21A*+ furnace: *80VSL0902120B*AHRI reference: 21562326817.008.10250002.10EPA 3947592 →
EVM5X49M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562328117.008.10246002.12EPA 3947603 →
EVM5X49M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562329717.008.10250002.12EPA 3947621 →
EVM5X49M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562333517.008.10248002.10EPA 3947658 →
EVM5X49M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562336517.008.10252002.10EPA 3947689 →
EVM5X49M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562337917.008.10250002.10EPA 3947702 →
EVM5X49M21A*+ furnace: *80VTL0902120B*AHRI reference: 21562339617.008.10250002.10EPA 3947720 →
EVM5X49M21A*+ furnace: *80VTL1102122B*AHRI reference: 21562341217.008.10248002.12EPA 3947736 →
EVM5X49M21A*+ furnace: *97CMN1002122B*AHRI reference: 21562348317.008.10252002.10EPA 3947792 →
EVM5X49M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562354517.008.10252002.10EPA 3947854 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →