Heil / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 12

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X48M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572187616.508.00242002.14EPA 3982287
EVM5X48M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572189016.508.00242002.12EPA 3982308
EVM5X49M21A*+ furnace: *97CTN0802120A*AHRI reference: 21572191716.508.00252002.10EPA 3982332
EVM5X49M21A*+ furnace: *97VTN0802120A*AHRI reference: 21572194816.508.00250002.12EPA 3982363
EVM5X49M21A*+ furnace: *97VTN1002120A*AHRI reference: 21572196416.508.00250002.10EPA 3982383
EVM5X60M21A*+ furnace: *80CSU0401712B*AHRI reference: 21572199216.508.00246002.14EPA 3982408
EVD5X60M21A*+ furnace: *97VTN0802120A*AHRI reference: 21572226816.508.00248002.12EPA 3982474
EVD5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 21572228416.508.00246002.14EPA 3982494
EVD5X61M21A*+ furnace: *97CTN0802120A*AHRI reference: 21572234016.508.00252002.10EPA 3982552
EVD5X61M24A*+ furnace: *80CSU1002120B*AHRI reference: 21572242916.508.00250002.26EPA 3982642
EVD5X61M24A*+ furnace: *97CTN0802120A*AHRI reference: 21572244316.508.00256002.10EPA 3982652
EVD5X61M24A*+ furnace: *97VTN1202422A*AHRI reference: 21572253516.508.00252002.12EPA 3982737
F5MA5*48L*C*AHRI reference: 21646428916.008.10246002.28EPA 3847202
EVM5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562299416.008.10248002.12EPA 3947398
EVM5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21562311216.008.10246002.12EPA 3947475
EVM5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21562312616.008.10248002.10EPA 3947489
EVM5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21562319116.008.10252002.08EPA 3947534
EVM5X48M21A*+ furnace: *96CTN1002122B*AHRI reference: 21562320516.008.10246002.12EPA 3947549
EVM5X48M21A*+ furnace: *96VTN0802120B*AHRI reference: 21562322216.008.10248002.10EPA 3947565
EVD5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21562422416.008.00246002.10EPA 3948191