Heil / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 23

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X36M12A*+ furnace: *80CSU0401712B*AHRI reference: 21572118216.007.80109002.10EPA 3981996 →
ESH5X36M12A*+ furnace: *80CSU0802120B*AHRI reference: 21572119616.007.80109002.10EPA 3982015 →
ESH5X36M12A*+ furnace: *97CTN1002122A*AHRI reference: 21572121016.007.80109002.08EPA 3982022 →
ESH5X36M12A*+ furnace: *97CTN1202422A*AHRI reference: 21572122416.007.80110002.08EPA 3982042 →
ESH5X36M12A*+ furnace: *97VTN1002120A*AHRI reference: 21572124116.007.80110002.08EPA 3982061 →
ESH5X36M12A*+ furnace: *97VTN1002122A*AHRI reference: 21572125616.007.80109002.10EPA 3982079 →
ESH5X36M12A*+ furnace: *96VTN0401410B*AHRI reference: 21565294016.008.00112002.05EPA 3996874 →
ESH5X36M12A*+ furnace: *96CTN0401410B*AHRI reference: 21565280816.008.00112002.05EPA 3996889 →
ESH5X36M12A*+ furnace: *96VTN0601412B*AHRI reference: 21565298716.008.00111002.05EPA 3996903 →
ESH5X24M12A*+ furnace: *80CTL1352422B*AHRI reference: 21564923816.008.00111002.05EPA 3996927 →
ESH5X24M12A*+ furnace: *80CTL0902120B*AHRI reference: 21564919716.008.00111002.05EPA 3996959 →
ESH5X24M12A*+ furnace: *96VSN0802120B*AHRI reference: 21564968216.008.00111002.05EPA 3996973 →
ESH5X30M12A*+ furnace: *80CTL0451712B*AHRI reference: 21565054816.008.00111002.05EPA 3997039 →
ESH5X36M12A*+ furnace: *96VSN0601412B*AHRI reference: 21565256216.008.00111002.05EPA 3997075 →
ESH5X36M12A*+ furnace: *96VSN0401712B*AHRI reference: 21565254316.008.00112002.05EPA 3997087 →
ESH5X24M12A*+ furnace: *97CTN1202422A*AHRI reference: 21571297316.008.00111002.05EPA 3997088 →
ESH5X36M12A*+ furnace: *96VSN0401410B*AHRI reference: 21565252416.008.00112002.05EPA 3997110 →
ESH5X24M12A*+ furnace: *80VTL0902120B*AHRI reference: 21564934116.008.00111002.05EPA 3997122 →
ESH5X24M12A*+ furnace: *96CTN0601714B*AHRI reference: 21564988916.008.00111002.05EPA 3997175 →
ESH5X24M12A*+ furnace: *95MSU0401712A*AHRI reference: 21564974316.007.80112002.00EPA 3997192 →