SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for N5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 187 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5187 / 187
EER2 · BTU/Wh11.7–13187 / 187
HSPF2 · BTU/Wh7.8–8.5187 / 187
Cooling capacity · BTU/h22,200–24,400187 / 187
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000187 / 187
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200187 / 187
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900187 / 187
COP at 5°F / −15°C1.96–2.26187 / 187
Equipment / loop typeHP - Split System187 / 187
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)187 / 187
Compressor stagingSingle stage187 / 187
Connected capabilityNo187 / 187

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X31M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21420498315.507.80113001.98EPA 3408288
EA*5X37M21A*+ furnace: *80VSL0902120B*AHRI reference: 21420171115.507.80116002.14EPA 3408409
EA*5X37M21A*+ furnace: *80MSU1002120A*AHRI reference: 21420173915.507.80116002.14EPA 3408478
EVD5X38M17A*+ furnace: *96VSN0601716B*AHRI reference: 21420760615.507.80114001.98EPA 3408488
EVD5X38M17A*+ furnace: *96VSN0801716B*AHRI reference: 21420763115.507.80113001.98EPA 3408503
EA*5X37M21A*+ furnace: *80CTL0702120B*AHRI reference: 21420190115.507.80116002.14EPA 3408570
EA*5X37M21A*+ furnace: *80CTL0901716B*AHRI reference: 21420192815.507.80115002.14EPA 3408599
EA*5X37M21A*+ furnace: *80CTL0701716B*AHRI reference: 21420187415.507.80115002.14EPA 3408622
EA*5X37M17A*+ furnace: *80CTL0701412B*AHRI reference: 21420016215.507.80112002.08EPA 3408633
EA*5X37M17A*+ furnace: *80CTL0701716B*AHRI reference: 21420018915.507.80113002.08EPA 3408661
EA*5X37M17A*+ furnace: *80CTL0901716B*AHRI reference: 21420021615.507.80113002.08EPA 3408686
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21420275315.507.80116002.14EPA 3408718
EVM5X31M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21420349015.507.80113001.98EPA 3408742
EVD5X31M17A*+ furnace: *80VTL0701716B*AHRI reference: 21420518315.507.80113001.98EPA 3408782
EA*5X37M17A*+ furnace: *95MSU0601716A*AHRI reference: 21420102415.507.80113002.08EPA 3408805
EVD5X38M17A*+ furnace: *96VTN0601716B*AHRI reference: 21420774915.507.80114001.98EPA 3408886
EA*5X37M17A*+ furnace: *96CTN0601714B*AHRI reference: 21420110715.507.80114002.08EPA 3408947
EA*5X37M17A*+ furnace: *96CTN0801714B*AHRI reference: 21420113415.507.80113002.08EPA 3408975
EA*5X37M21A*+ furnace: *92MSN0801716A*AHRI reference: 21421177515.507.80114002.14EPA 3409188
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 21421180515.507.80115002.16EPA 3409217