N5H5S24*K*AAA*
PERFORMANCE 16 SEER2 HP · source records, page 2
187 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 187 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 187 / 187 |
| EER2 · BTU/Wh | 11.7–13 | 187 / 187 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 187 / 187 |
| Cooling capacity · BTU/h | 22,200–24,400 | 187 / 187 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–24,000 | 187 / 187 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 187 / 187 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 187 / 187 |
| COP at 5°F / −15°C | 1.96–2.26 | 187 / 187 |
| Equipment / loop type | HP - Split System | 187 / 187 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 187 / 187 |
| Compressor staging | Single stage | 187 / 187 |
| Connected capability | No | 187 / 187 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 214210621 | 16.00 | 7.80 | 11400 | 2.12 | EPA 3410896 → |
EA*5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 214211544 | 16.00 | 7.80 | 11600 | 2.14 | EPA 3411047 → |
EA*5X37M21A*+ furnace: *97CMN1002122A*AHRI reference: 214211571 | 16.00 | 7.80 | 11200 | 2.12 | EPA 3411074 → |
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 214211598 | 16.00 | 7.80 | 11500 | 2.14 | EPA 3411101 → |
EVD5X38M17A*+ furnace: *80MSU0601716A*AHRI reference: 214214236 | 16.00 | 7.80 | 11200 | 2.02 | EPA 3411137 → |
EVM5X32M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 214212545 | 16.00 | 7.80 | 11200 | 1.98 | EPA 3411159 → |
EVD5X31M17A*+ furnace: *80MSU0601716A*AHRI reference: 214213277 | 16.00 | 7.80 | 11200 | 2.00 | EPA 3411206 → |
EVD5X38M17A*+ furnace: *80VSL0701716B*AHRI reference: 214214119 | 16.00 | 7.80 | 11300 | 1.98 | EPA 3411300 → |
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 214211625 | 16.00 | 7.80 | 11500 | 2.14 | EPA 3411326 → |
EVD5X38M17A*+ furnace: *80VSL0901716B*AHRI reference: 214214144 | 16.00 | 7.80 | 11400 | 2.00 | EPA 3411373 → |
EA*5X37M21A*+ furnace: *80CSU0401712A*AHRI reference: 214210885 | 16.00 | 7.80 | 11200 | 2.12 | EPA 3411456 → |
EVM5X32M17A*+ furnace: *80VSL0901716B*AHRI reference: 214212649 | 16.00 | 7.80 | 11400 | 1.98 | EPA 3411898 → |
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 215800257 | 16.00 | 8.00 | 11500 | 2.10 | EPA 3653637 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 215800282 | 16.00 | 8.00 | 11400 | 2.10 | EPA 3653662 → |
FM(C,U)5Z30**AL*AHRI reference: 215828937 | 16.00 | 7.80 | 11100 | 1.98 | EPA 3713350 → |
FM(C,U)5Z36**AL*AHRI reference: 215828969 | 16.00 | 7.80 | 11100 | 1.98 | EPA 3713383 → |
FHMA5*36L*B*AHRI reference: 214179777 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3404566 → |
FTMA5X24L0B*AHRI reference: 214179861 | 15.50 | 7.80 | 11200 | 2.08 | EPA 3404630 → |
EA*5X25M17A*+ furnace: *96MSN0601716A*AHRI reference: 214198027 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405043 → |
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 214197599 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405467 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →