Heil / AIR-SOURCE HEAT PUMP

H5H8T36*K*AAA*

Mainline 18 SEER2 HP · source records, page 3

188 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for H5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5188 / 188
EER2 · BTU/Wh11.7–13188 / 188
HSPF2 · BTU/Wh7.8–8.5188 / 188
Cooling capacity · BTU/h33,800–38,000188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200188 / 188
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600188 / 188
COP at 5°F / −15°C1.84–2.4188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingTwo-stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635731115.508.00193002.24EPA 3807881
EA*5X37M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635731915.508.00193002.24EPA 3807889
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635733515.508.10193002.28EPA 3807905
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635734315.508.10195002.28EPA 3807913
EA*5X37M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21635736715.508.00193002.24EPA 3807921
EA*5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635875115.508.00191002.26EPA 3807933
EA*5X42M21A*+ furnace: *96VTN1002122B*AHRI reference: 21635802315.508.10188002.28EPA 3807937
EA*5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635887915.508.10193002.26EPA 3807977
EA*5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635875915.508.00191002.26EPA 3807991
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635877515.508.10192002.28EPA 3808007
EA*5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635878315.508.10191002.28EPA 3808015
ESH5X42M12A*+ furnace: *80MSU0802120A*AHRI reference: 21635965515.508.10190002.28EPA 3808029
EA*5X37M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635740715.508.00194002.24EPA 3808064
EA*5X37M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635743115.508.10193002.28EPA 3808071
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635743915.508.10194002.28EPA 3808079
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21635745515.508.10193002.28EPA 3808095
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21635746315.508.10194002.28EPA 3808103
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21635747115.508.10194002.30EPA 3808111
EA*5X37M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21635750315.508.00194002.24EPA 3808119
EA*5X43M21A*+ furnace: *80VSL0701716B*AHRI reference: 21635816715.508.10194002.26EPA 3808127