H5H6S36*K*AAA*
MAINLINE 16 SEER2 HP
30 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H6S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.5 | 30 / 30 |
| EER2 · BTU/Wh | 11.7–13 | 30 / 30 |
| HSPF2 · BTU/Wh | 7.8 | 30 / 30 |
| Cooling capacity · BTU/h | 33,800–36,800 | 30 / 30 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,200 | 30 / 30 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 30 / 30 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,700–18,100 | 30 / 30 |
| COP at 5°F / −15°C | 2–2.24 | 30 / 30 |
| Equipment / loop type | HP - Split System | 30 / 30 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 30 / 30 |
| Compressor staging | Single stage | 30 / 30 |
| Connected capability | No | 30 / 30 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FHMA5*48L*C*AHRI reference: 214165317 | 15.50 | 7.80 | 17500 | 2.24 | EPA 3404298 → |
FTMA5B48L0C*AHRI reference: 214165261 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404410 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277697 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415825 → |
FMA5X36**AL*AHRI reference: 214424323 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425201 → |
F5MA5*48L*C*AHRI reference: 216464038 | 15.50 | 7.80 | 17500 | 2.24 | EPA 3846950 → |
FEVA0048**+NAVA54801CKAHRI reference: 217051671 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4001132 → |
EVD5X42M24A*+ furnace: *80MSU1002120A*AHRI reference: 214155651 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401961 → |
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 214154320 | 15.20 | 7.80 | 17000 | 2.18 | EPA 3402081 → |
EA*5X43M21A*+ furnace: *80CSU1002120A*AHRI reference: 214154328 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3402089 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 214154835 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3402098 → |
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 214154843 | 15.20 | 7.80 | 17300 | 2.20 | EPA 3402106 → |
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 214153848 | 15.20 | 7.80 | 17100 | 2.16 | EPA 3402197 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214154755 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402341 → |
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214154763 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3402349 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 214154787 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402357 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214154368 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3402540 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214154376 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3402550 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 214154891 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402559 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 214154915 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402568 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 214155003 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3402583 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →