Heil / AIR-SOURCE HEAT PUMP

H5H6S31*K*AAA*

MAINLINE 16 SEER2 HP

38 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for H5H6S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 38 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1638 / 38
EER2 · BTU/Wh11.7–1338 / 38
HSPF2 · BTU/Wh7.8–838 / 38
Cooling capacity · BTU/h27,400–29,40038 / 38
Heating capacity at 47°F / 8.3°C · BTU/h29,200–30,60038 / 38
Heating capacity at 17°F / −8.3°C · BTU/h17,300–18,20038 / 38
Heating capacity at 5°F / −15°C · BTU/h13,100–14,00038 / 38
COP at 5°F / −15°C2–2.0638 / 38
Equipment / loop typeHP - Split System38 / 38
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)38 / 38
Compressor stagingSingle stage38 / 38
Connected capabilityNo38 / 38

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FHMA5*42L*C*AHRI reference: 21768728716.008.00134002.05EPA 4506488
FM(C,U)5Z30**AL*AHRI reference: 21768729016.008.00134002.00EPA 4506496
FM(C,U)5Z36**AL*AHRI reference: 21768729116.008.00134002.00EPA 4506497
FMA5X30**AL*AHRI reference: 21768729416.008.00137002.00EPA 4506499
FMA5X36**AL*AHRI reference: 21768729516.008.00137002.00EPA 4506500
F5MA5*42L*C*AHRI reference: 21772144716.008.00134002.05EPA 4509410
FHMA5*30L*B*AHRI reference: 21768728515.507.80134002.00EPA 4506487
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21771731315.508.00140002.06EPA 4508966
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21771732115.508.00140002.04EPA 4508973
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21771725715.508.00140002.06EPA 4508982
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21771726515.508.00140002.06EPA 4508991
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21771729715.508.00140002.06EPA 4508998
EA*5X37M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21771718515.508.00139002.06EPA 4509006
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 21771748915.508.00140002.06EPA 4509012
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 21771749715.508.00140002.06EPA 4509020
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 21771750515.508.00140002.06EPA 4509028
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21771720115.508.00140002.06EPA 4509038
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21771764715.508.00140002.06EPA 4509048
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 21771840915.508.00140002.06EPA 4509055
EA*5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 21771774315.508.00140002.06EPA 4509162

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →