Heil / AIR-SOURCE HEAT PUMP

H5H3V48*K*AAA*

QUIETCOMFORT DELUXE 23 VS HP · source records, page 4

138 published source records · source checked Sep 21, 2026

SEER2 range19.5–23BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for H5H3V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 138 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19.5–23138 / 138
EER2 · BTU/Wh10–12.5138 / 138
HSPF2 · BTU/Wh8–9.5138 / 138
Cooling capacity · BTU/h43,000–46,500138 / 138
Heating capacity at 47°F / 8.3°C · BTU/h48,000–53,500135 / 138
Heating capacity at 17°F / −8.3°C · BTU/h39,000–43,500138 / 138
Heating capacity at 5°F / −15°C · BTU/h35,600–38,500138 / 138
COP at 5°F / −15°C1.8–2138 / 138
Equipment / loop typeHP - Split System138 / 138
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)138 / 138
Compressor stagingContinuously variable138 / 138
Connected capabilityNo138 / 138

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21593437621.009.50368001.92EPA 4012334 →
EA*5X61M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21593434621.009.50368001.90EPA 4012361 →
EA*5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21593416621.009.50370001.90EPA 4012374 →
EVD5X48M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21593788620.508.10380001.95EPA 3724606 →
EVD5X48M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21593789620.508.10380001.90EPA 3724616 →
EVD5X48M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21593790620.508.10380001.95EPA 3724627 →
EA*5X48M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21593397620.509.50366002.00EPA 3724680 →
EVM5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21593755620.508.10380001.90EPA 3725528 →
EVM5X60M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21593756620.508.10380001.95EPA 3725538 →
EA*5X61M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21593423620.509.40374002.00EPA 3726075 →
EVD5X49M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21593808620.508.10380001.90EPA 3726685 →
EVD5X49M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21593810620.508.10380001.90EPA 3727309 →
EVD5X49M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21593811620.508.10380001.95EPA 3727318 →
ESH5X48M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21593445620.509.00364001.82EPA 3727517 →
ESH5X48M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21593446620.509.00364001.82EPA 3727527 →
EA*5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21593436620.509.50374002.00EPA 3728038 →
EA*5X48M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21593402620.509.00366002.00EPA 3728282 →
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21593454620.509.00366001.82EPA 3729512 →
ESH5X60M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21593458620.509.00364001.84EPA 3729671 →
EVD5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21593836620.508.10380001.90EPA 3729994 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.