H5H0V48*K*AAA*
QUIETCOMFORT DELUXE 20 VS HP · source records, page 17
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215681355 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3975816 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681395 | 17.50 | 9.00 | 33600 | 2.06 | EPA 3975860 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215681455 | 17.50 | 9.00 | 33800 | 2.08 | EPA 3975919 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681475 | 17.50 | 9.00 | 33600 | 2.06 | EPA 3975942 → |
EA*5X61M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215681485 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3975949 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215674076 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3967936 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215674016 | 17.00 | 9.00 | 35000 | 2.02 | EPA 3967975 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215674096 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3968051 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 215674106 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3968056 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215674326 | 17.00 | 9.00 | 34600 | 2.06 | EPA 3968577 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675135 | 17.00 | 8.50 | 33600 | 2.08 | EPA 3968696 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215681315 | 17.00 | 9.00 | 34200 | 2.04 | EPA 3975329 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681335 | 17.00 | 9.00 | 34000 | 2.04 | EPA 3975347 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215681685 | 17.00 | 8.50 | 33800 | 2.08 | EPA 3975410 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215681695 | 17.00 | 8.50 | 33600 | 2.06 | EPA 3975422 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215681345 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3975806 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215674702 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968345 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215674843 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968379 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215674865 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968390 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215674883 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968396 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →