| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215681405 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975866 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215681415 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975875 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215681425 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975884 → |
EA*5X61M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681435 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975893 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681445 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975909 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215681465 | 18.00 | 9.00 | 33400 | 2.08 | EPA 3975923 → |
EA*5X61M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215681495 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975953 → |
EA*5X61M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215681505 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975962 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681515 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975970 → |
EA*5X61M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215681525 | 18.00 | 9.00 | 33400 | 2.08 | EPA 3975986 → |
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681535 | 18.00 | 9.00 | 33600 | 2.08 | EPA 3975996 → |
EVD5X48M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215682195 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3976503 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215682115 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3976764 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215682105 | 18.00 | 9.00 | 36400 | 2.02 | EPA 3976765 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215682135 | 18.00 | 9.00 | 36400 | 2.02 | EPA 3976788 → |
EVD5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215682145 | 18.00 | 9.00 | 37000 | 1.98 | EPA 3976797 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215673986 | 17.50 | 9.00 | 34200 | 2.04 | EPA 3967853 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215674086 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3967953 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215674006 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3967967 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215674026 | 17.50 | 9.00 | 34400 | 2.04 | EPA 3967986 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →