D5CUHAH24AAK+KSAIC0701230
Crossover Heat Pump · source records, page 9
499 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 499 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 499 / 499 |
| EER2 · BTU/Wh | 10–11 | 499 / 499 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 499 / 499 |
| Cooling capacity · BTU/h | 22,600–25,000 | 499 / 499 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 499 / 499 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 499 / 499 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 499 / 499 |
| COP at 5°F / −15°C | 1.85–2.06 | 499 / 499 |
| Equipment / loop type | HP - Split System | 499 / 499 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 499 / 499 |
| Compressor staging | Continuously variable | 499 / 499 |
| Connected capability | No | 499 / 499 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X36M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218487012 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631183 → |
EA*5X36M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218487005 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631190 → |
EA*5X36M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 218486998 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631197 → |
EA*5X36M17A*+ furnace: *96VTN0401410B*Cold climate designationAHRI reference: 218486991 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631204 → |
EA*5X36M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218486977 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631218 → |
EA*5X36M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218486963 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631232 → |
EA*5X36M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 218486956 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631239 → |
EA*5X36M17A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 218486949 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631246 → |
EA*5X36M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 218486942 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631253 → |
EA*5X30M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218486879 | 16.50 | 8.50 | 19700 | 1.90 | EPA 4631316 → |
EA*5X30M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218486858 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631337 → |
EA*5X30M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218486851 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631344 → |
EA*5X30M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218486844 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631351 → |
EA*5X30M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218486837 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631358 → |
EA*5X30M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218486830 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631365 → |
EA*5X30M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218486802 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631393 → |
EA*5X30M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218486795 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631400 → |
EA*5X30M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218486788 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631407 → |
EA*5X30M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 218486781 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631414 → |
EA*5X30M14A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218486704 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631491 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →