D5CUHAH18AAK+KSAIC0701230
Crossover Heat Pump · source records, page 3
63 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH18AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 63 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 63 / 63 |
| EER2 · BTU/Wh | 10–11 | 63 / 63 |
| HSPF2 · BTU/Wh | 8.1–9 | 63 / 63 |
| Cooling capacity · BTU/h | 17,400–18,700 | 63 / 63 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,900–20,200 | 63 / 63 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,400–15,300 | 63 / 63 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,300–17,600 | 63 / 63 |
| COP at 5°F / −15°C | 1.85–2.04 | 63 / 63 |
| Equipment / loop type | HP - Split System | 63 / 63 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 63 / 63 |
| Compressor staging | Continuously variable | 63 / 63 |
| Connected capability | No | 63 / 63 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X25M17A*+ furnace: *92MSN0601714A*Cold climate designationAHRI reference: 218483956 | 15.20 | 8.50 | 16400 | 1.95 | EPA 4628920 → |
EA*5X25M17A*+ furnace: *92MSN0601412A*Cold climate designationAHRI reference: 218483949 | 15.20 | 8.10 | 16300 | 1.85 | EPA 4628927 → |
EA*5X25M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218483921 | 15.20 | 8.10 | 17100 | 1.90 | EPA 4628934 → |
EA*5X25M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218483886 | 15.20 | 8.10 | 17100 | 1.90 | EPA 4628962 → |
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218483879 | 15.20 | 8.50 | 16400 | 1.95 | EPA 4628969 → |
EA*5X30M14A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218483774 | 15.20 | 8.10 | 17200 | 1.90 | EPA 4629004 → |
EA*5X30M14A*+ furnace: *80MS(N,L)0701412A*Cold climate designationAHRI reference: 218483760 | 15.20 | 8.50 | 16500 | 1.90 | EPA 4629011 → |
EA*5X30M14A*+ furnace: *80MS(N,L)0451412A*Cold climate designationAHRI reference: 218483753 | 15.20 | 8.10 | 16500 | 1.85 | EPA 4629018 → |
EA*5X30M17A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218483619 | 15.20 | 8.50 | 16600 | 1.90 | EPA 4629032 → |
EA*5X30M17A*+ furnace: *92MSN0601714A*Cold climate designationAHRI reference: 218483612 | 15.20 | 8.50 | 16600 | 1.90 | EPA 4629039 → |
EA*5X30M17A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 218483535 | 15.20 | 8.10 | 16500 | 1.85 | EPA 4629060 → |
EA*5X30M17A*+ furnace: *80MS(N,L)0451412A*Cold climate designationAHRI reference: 218483507 | 15.20 | 8.10 | 16500 | 1.85 | EPA 4629081 → |
F5MA5*18L*A*Cold climate designationAHRI reference: 218483255 | 15.20 | 8.50 | 16800 | 1.94 | EPA 4629088 → |
FEVA0024**+NAVA53601CKCold climate designationAHRI reference: 218483241 | 15.20 | 8.50 | 16500 | 1.95 | EPA 4629095 → |
FEVB0024**+NAVA53601CKCold climate designationAHRI reference: 218483234 | 15.20 | 8.50 | 16500 | 1.95 | EPA 4629102 → |
FHMA5*18L*A*Cold climate designationAHRI reference: 218483227 | 15.20 | 8.50 | 16800 | 1.94 | EPA 4629109 → |
EA*5X19M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218484597 | 15.20 | 8.10 | 17000 | 1.90 | EPA 4629196 → |
EA*5X19M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 218484555 | 15.20 | 8.10 | 17000 | 1.90 | EPA 4629203 → |
EA*5X19M17A*+ furnace: *96MSN0801716A*Cold climate designationAHRI reference: 218484534 | 15.20 | 8.50 | 16600 | 1.95 | EPA 4629210 → |
EA*5X19M17A*+ furnace: *96MSN0601412A*Cold climate designationAHRI reference: 218484519 | 15.20 | 8.10 | 16400 | 1.85 | EPA 4629217 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.