B5H6S36*K*AAA*
MAINLINE 16 SEER2 HP
26 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H6S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 26 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.5 | 26 / 26 |
| EER2 · BTU/Wh | 11.7–13 | 26 / 26 |
| HSPF2 · BTU/Wh | 7.8 | 26 / 26 |
| Cooling capacity · BTU/h | 33,800–36,800 | 26 / 26 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,200 | 26 / 26 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 26 / 26 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,700–18,100 | 26 / 26 |
| COP at 5°F / −15°C | 2–2.24 | 26 / 26 |
| Equipment / loop type | HP - Split System | 26 / 26 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 26 / 26 |
| Compressor staging | Single stage | 26 / 26 |
| Connected capability | No | 26 / 26 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 218187424 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4581904 → |
FMA5X36**AL*AHRI reference: 218187420 | 15.50 | 7.80 | 17000 | 2.00 | EPA 4581906 → |
FEVB0048**+NAVA54801CKAHRI reference: 218187418 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4581907 → |
F5MA5*48L*C*AHRI reference: 218193500 | 15.50 | 7.80 | 17500 | 2.24 | EPA 4582118 → |
FHMA5*48L*C*AHRI reference: 218192493 | 15.50 | 7.80 | 17500 | 2.24 | EPA 4582256 → |
FTMA5B48L0C*AHRI reference: 218192484 | 15.50 | 7.80 | 16700 | 2.18 | EPA 4582259 → |
FM(C,U)5Z36**AL*AHRI reference: 218187423 | 15.20 | 7.80 | 17200 | 2.08 | EPA 4581905 → |
EA*5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 218187347 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4581908 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 218187344 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4581909 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 218191389 | 15.20 | 7.80 | 17500 | 2.20 | EPA 4582052 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 218191379 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4582057 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 218191361 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4582060 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 218191348 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582063 → |
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 218191338 | 15.20 | 7.80 | 17300 | 2.20 | EPA 4582068 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 218191335 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4582071 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 218191326 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582074 → |
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 218191320 | 15.20 | 7.80 | 17600 | 2.20 | EPA 4582077 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 218191317 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582080 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 218191288 | 15.20 | 7.80 | 17900 | 2.20 | EPA 4582083 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 218191269 | 15.20 | 7.80 | 18000 | 2.20 | EPA 4582086 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →