B5H6S31*K*AAA*
MAINLINE 16 SEER2 HP
38 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H6S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 38 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 38 / 38 |
| EER2 · BTU/Wh | 11.7–13 | 38 / 38 |
| HSPF2 · BTU/Wh | 7.8–8 | 38 / 38 |
| Cooling capacity · BTU/h | 27,400–29,400 | 38 / 38 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,200–30,600 | 38 / 38 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,300–18,200 | 38 / 38 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,100–14,000 | 38 / 38 |
| COP at 5°F / −15°C | 2–2.06 | 38 / 38 |
| Equipment / loop type | HP - Split System | 38 / 38 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 38 / 38 |
| Compressor staging | Single stage | 38 / 38 |
| Connected capability | No | 38 / 38 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FMA5X36**AL*AHRI reference: 218188634 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4581711 → |
FMA5X30**AL*AHRI reference: 218188633 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4581712 → |
FM(C,U)5Z36**AL*AHRI reference: 218188630 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4581714 → |
FM(C,U)5Z30**AL*AHRI reference: 218188629 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4581715 → |
FHMA5*42L*C*AHRI reference: 218188626 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4581716 → |
F5MA5*42L*C*AHRI reference: 218190802 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4582093 → |
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 218188997 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581693 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 218188996 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581694 → |
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 218188995 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581695 → |
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 218188974 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4581696 → |
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 218188973 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581697 → |
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 218188971 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581698 → |
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 218188967 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581699 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 218188966 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581700 → |
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 218188959 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4581701 → |
EA*5X37M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 218188957 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4581702 → |
FHMA5*30L*B*AHRI reference: 218188624 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4581717 → |
F5MA5*30L*B*AHRI reference: 218190800 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4582094 → |
FEVB0036**+NAVA53601CKAHRI reference: 218190799 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4582095 → |
FEVA0036**+NAVA53601CKAHRI reference: 218190798 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4582096 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →