B5H3V36*K*AAA*
QUIETCOMFORT DELUXE 23 VS HP · source records, page 8
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X44M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218411144 | 21.50 | 8.50 | 28600 | 2.02 | EPA 4604350 → |
EVM5X44M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218411136 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4604358 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218413120 | 21.50 | 8.50 | 28800 | 2.06 | EPA 4606374 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218413112 | 21.50 | 8.50 | 28200 | 2.06 | EPA 4606382 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218413104 | 21.50 | 8.50 | 28800 | 2.06 | EPA 4606390 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218413096 | 21.50 | 8.50 | 28600 | 2.00 | EPA 4606398 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218413048 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606446 → |
EVD5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218413024 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606470 → |
EVD5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218413000 | 21.50 | 8.50 | 28400 | 2.06 | EPA 4606494 → |
EVD5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218412976 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606518 → |
EVD5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218412944 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606550 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218412928 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606566 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218412896 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606598 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218412888 | 21.50 | 8.50 | 28800 | 2.04 | EPA 4606606 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218412872 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606622 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218412864 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4606630 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218412840 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606654 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218412832 | 21.50 | 8.50 | 29000 | 2.06 | EPA 4606662 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218412800 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606694 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218412792 | 21.50 | 8.50 | 28800 | 2.04 | EPA 4606702 → |