B5H3V36*K*AAA*
QUIETCOMFORT DELUXE 23 VS HP · source records, page 19
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X36M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218411856 | 20.00 | 8.10 | 29000 | 2.00 | EPA 4607630 → |
EVD5X36M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218411832 | 20.00 | 8.10 | 27200 | 2.00 | EPA 4607641 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218409696 | 19.50 | 9.00 | 26800 | 1.94 | EPA 4601798 → |
EA*5X48M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218409664 | 19.50 | 9.00 | 26000 | 1.96 | EPA 4601830 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218409648 | 19.50 | 9.00 | 26800 | 1.92 | EPA 4601846 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218409640 | 19.50 | 9.00 | 26800 | 1.94 | EPA 4601854 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218409632 | 19.50 | 9.00 | 26000 | 1.96 | EPA 4601862 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218409624 | 19.50 | 9.00 | 26800 | 1.94 | EPA 4601870 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218409584 | 19.50 | 9.00 | 27200 | 1.94 | EPA 4601910 → |
EA*5X43M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218409560 | 19.50 | 9.50 | 26000 | 2.08 | EPA 4601934 → |
EA*5X43M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218409552 | 19.50 | 9.00 | 26200 | 1.98 | EPA 4601942 → |
EA*5X42M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218409536 | 19.50 | 9.00 | 26800 | 1.94 | EPA 4601958 → |
EA*5X42M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218409528 | 19.50 | 9.00 | 27200 | 1.92 | EPA 4601966 → |
EA*5X42M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218409504 | 19.50 | 9.00 | 26800 | 1.94 | EPA 4601990 → |
EA*5X42M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218409496 | 19.50 | 9.00 | 27000 | 1.92 | EPA 4601998 → |
EA*5X42M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218409488 | 19.50 | 9.00 | 26400 | 1.94 | EPA 4602006 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218409472 | 19.50 | 9.00 | 26800 | 1.94 | EPA 4602022 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218409464 | 19.50 | 9.00 | 27200 | 1.92 | EPA 4602030 → |
EA*5X42M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218409432 | 19.50 | 9.00 | 27200 | 1.92 | EPA 4602062 → |
EA*5X42M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218409408 | 19.50 | 9.00 | 26800 | 1.94 | EPA 4602086 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.