Heil / AIR-SOURCE HEAT PUMP

B5H0V60*K*AAA*

QUIETCOMFORT DELUXE 20 VS HP · source records, page 5

96 published source records · source checked Sep 21, 2026

SEER2 range16.5–20BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for B5H0V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 96 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.5–2096 / 96
EER2 · BTU/Wh8–1096 / 96
HSPF2 · BTU/Wh8.5–996 / 96
Cooling capacity · BTU/h54,000–57,50096 / 96
Heating capacity at 47°F / 8.3°C · BTU/h57,500–65,00096 / 96
Heating capacity at 17°F / −8.3°C · BTU/h50,000–57,50096 / 96
Heating capacity at 5°F / −15°C · BTU/h40,500–46,00096 / 96
COP at 5°F / −15°C1.86–2.1296 / 96
Equipment / loop typeHP - Split System96 / 96
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)96 / 96
Compressor stagingContinuously variable96 / 96
Connected capabilityNo96 / 96

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21816733418.009.00445002.08EPA 4597099
EA*5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816719917.508.50430001.88EPA 4579601
EA*5X60M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816716017.508.50425001.86EPA 4579640
EVD5X61M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816710917.509.00460002.06EPA 4579685
EVD5X60M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816707917.508.50455001.94EPA 4579715
EVD5X60M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816705217.508.50460001.94EPA 4579742
EVM5X60M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816699217.508.50455001.94EPA 4579802
EVM5X60M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816696217.508.50460001.94EPA 4579832
ESH5X60M12A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21816731617.008.50420001.90EPA 4579511
ESH5X60M12A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21816731317.008.50420001.90EPA 4579514
ESH5X60M12A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21816729817.008.50420001.90EPA 4579520
ESH5X60M12A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21816725017.008.50420001.90EPA 4579562
ESH5X60M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21816724717.008.50420001.90EPA 4579565
ESH5X60M12A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21816724417.008.50420001.90EPA 4579568
ESH5X60M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21816724117.008.50420001.90EPA 4579571
ESH5X60M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21816723216.508.50420001.90EPA 4579577

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →