B5H0V48*K*AAA*
QUIETCOMFORT DELUXE 20 VS HP · source records, page 4
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X60M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166746 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4580045 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166737 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4580054 → |
EVM5X49M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218166734 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4580057 → |
EVM5X49M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166731 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4580060 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166722 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4580069 → |
EVM5X49M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166713 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4580078 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218166542 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4580231 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218166539 | 19.00 | 9.00 | 37200 | 1.98 | EPA 4580234 → |
EVD5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218166536 | 19.00 | 9.00 | 36600 | 2.10 | EPA 4580237 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218166527 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4580246 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218166521 | 19.00 | 9.00 | 36400 | 2.02 | EPA 4580252 → |
EVD5X61M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218166509 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4580264 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218166494 | 19.00 | 9.00 | 37000 | 2.00 | EPA 4580279 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218166491 | 19.00 | 9.00 | 37000 | 2.00 | EPA 4580282 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218166488 | 19.00 | 9.00 | 37200 | 1.98 | EPA 4580285 → |
EVD5X60M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218166482 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4580291 → |
EVD5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218166479 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4580294 → |
EVD5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218166473 | 19.00 | 9.00 | 36400 | 2.02 | EPA 4580300 → |
EVD5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218166467 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4580306 → |
EVD5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218166464 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4580309 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →