Heil / AIR-SOURCE HEAT PUMP

B5H0V36*K*AAA*

QUIETCOMFORT DELUXE 20 VS HP · source records, page 14

275 published source records · source checked Sep 21, 2026

SEER2 range16–19.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,800–35,400BTU/h

Each efficiency range summarizes published EPA records for B5H0V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19.5275 / 275
EER2 · BTU/Wh9–11.5275 / 275
HSPF2 · BTU/Wh8.1–9.5275 / 275
Cooling capacity · BTU/h32,800–35,400275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,000275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h29,400–31,800275 / 275
Heating capacity at 5°F / −15°C · BTU/h23,600–25,800275 / 275
COP at 5°F / −15°C1.64–2.04275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingContinuously variable275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X48M12A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21816238516.008.50254001.78EPA 4578731
ESH5X42M12A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 21816230116.008.50256001.76EPA 4578815
ESH5X42M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21816229516.008.50254001.78EPA 4578821
ESH5X42M12A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21816229216.008.50254001.78EPA 4578824
ESH5X42M12A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21816226816.008.50256001.76EPA 4578848
ESH5X36M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21816226516.008.50254001.76EPA 4578851
ESH5X36M12A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21816225916.008.50258001.76EPA 4578857
ESH5X36M12A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21816224416.008.50256001.76EPA 4578872
ESH5X36M12A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816224116.008.50256001.76EPA 4578875
ESH5X36M12A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 21816223816.008.10258001.80EPA 4578878
ESH5X36M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21816223216.008.50254001.76EPA 4578884
ESH5X36M12A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21816222916.008.50256001.76EPA 4578887
ESH5X36M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21816222616.008.50254001.76EPA 4578890
ESH5X36M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21816222316.008.50254001.76EPA 4578893
ESH5X36M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21816221716.008.50254001.76EPA 4578899

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →