| SEER2 · BTU/Wh | 15.2–17.2 | 83 / 83 |
| EER2 · BTU/Wh | 10.2–11 | 83 / 83 |
| HSPF2 · BTU/Wh | 8.1–8.8 | 83 / 83 |
| Cooling capacity · BTU/h | 17,900–18,900 | 83 / 83 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–18,600 | 83 / 83 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,000–15,600 | 83 / 83 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,600–14,000 | 83 / 83 |
| COP at 5°F / −15°C | 1.8–2 | 83 / 83 |
| Equipment / loop type | HP - Split System | 83 / 83 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 83 / 83 |
| Compressor staging | Continuously variable | 83 / 83 |
| Connected capability | No | 83 / 83 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCHC30BT5****+TDR+ furnace: NF93U045T3BF***Cold climate designationAHRI reference: 218685641 | 15.90 | 8.30 | 13900 | 1.90 | EPA 4672376 → |
NCHC24BT5****+TDR+ furnace: NF93U045T3BF***Cold climate designationAHRI reference: 218685628 | 15.90 | 8.30 | 13900 | 1.90 | EPA 4672387 → |
NCHC24AT5****+TDR+ furnace: NF80L070T3AF***Cold climate designationAHRI reference: 218685617 | 15.90 | 8.30 | 14000 | 1.90 | EPA 4672396 → |
NCUC24AT5****+TDR+ furnace: NF80L070T3AF***Cold climate designationAHRI reference: 218685589 | 15.90 | 8.30 | 14000 | 1.90 | EPA 4672414 → |
NCHC24AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 218685324 | 15.90 | 8.30 | 14000 | 1.90 | EPA 4672463 → |
NCUC24AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 218685302 | 15.90 | 8.30 | 14000 | 1.90 | EPA 4672477 → |
NCDC24BT5****+TDR+ furnace: NF93D070T3BF***Cold climate designationAHRI reference: 218685646 | 15.80 | 8.40 | 13900 | 1.90 | EPA 4672372 → |
NCUC30BT5****+TDR+ furnace: NF93U070T3BF***Cold climate designationAHRI reference: 218685616 | 15.80 | 8.20 | 13900 | 1.90 | EPA 4672397 → |
NCUC30BT5****+TDR+ furnace: NF80U090T3BF***Cold climate designationAHRI reference: 218685610 | 15.80 | 8.20 | 13900 | 1.90 | EPA 4672401 → |
NCDC24BT5****+TDR+ furnace: NF93D045T3BF***Cold climate designationAHRI reference: 218685645 | 15.70 | 8.40 | 13900 | 1.90 | EPA 4672373 → |
NCUC30BT5****+TDR+ furnace: NF93U045T3BF***Cold climate designationAHRI reference: 218685615 | 15.70 | 8.20 | 14000 | 1.90 | EPA 4672398 → |
NCUC24BT5****+TDR+ furnace: NF93U070T3BF***Cold climate designationAHRI reference: 218685602 | 15.70 | 8.30 | 14000 | 1.90 | EPA 4672406 → |
NCUC24BT5****+TDR+ furnace: NF80U090T3BF***Cold climate designationAHRI reference: 218685596 | 15.70 | 8.30 | 13900 | 1.90 | EPA 4672410 → |
NCHC30AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 218685333 | 15.70 | 8.60 | 13800 | 2.00 | EPA 4672456 → |
NCHC30AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 218685332 | 15.70 | 8.60 | 13800 | 2.00 | EPA 4672457 → |
NCUC30AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 218685315 | 15.70 | 8.20 | 13900 | 1.90 | EPA 4672468 → |
NCUC30AT5****+TDR+ furnace: NF80U045S3A***Cold climate designationAHRI reference: 218685314 | 15.70 | 8.20 | 13900 | 1.90 | EPA 4672469 → |
NCUC30AT5****+TDR+ furnace: NF80U045T3A***Cold climate designationAHRI reference: 218685312 | 15.70 | 8.20 | 13900 | 1.90 | EPA 4672471 → |
NCUC24BT5****+TDR+ furnace: NF93U045T3BF***Cold climate designationAHRI reference: 218685601 | 15.60 | 8.30 | 14000 | 1.90 | EPA 4672407 → |
NCHC24AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 218685326 | 15.60 | 8.30 | 13900 | 1.90 | EPA 4672461 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →