1U60T3PE*HE
Connect · source records, page 8
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 1U60T3PE*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,500–56,000 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–43,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC48CT5****+TDR+ furnace: NF96U110S5C***Cold climate designationAHRI reference: 217270577 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4027444 → |
NCHC42CT5****+TDR+ furnace: NF80X100S5C***Cold climate designationAHRI reference: 217270578 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4027445 → |
NCHC42CT5****+TDR+ furnace: NF80L110S5C***Cold climate designationAHRI reference: 217270579 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4027446 → |
NCHC42CT5****+TDR+ furnace: NF80U110T5C***Cold climate designationAHRI reference: 217270580 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4027447 → |
NCHC42CT5****+TDR+ furnace: NF96U110S5C***Cold climate designationAHRI reference: 217270582 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4027449 → |
NCHC48CT5****+TDR+ furnace: NF97X080V4C***Cold climate designationAHRI reference: 217270583 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4027450 → |
NCHC48CT5****+TDR+ furnace: NF98U090M4C***Cold climate designationAHRI reference: 217270584 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4027451 → |
NCHC48CT5****+TDR+ furnace: NF80X100S5C***Cold climate designationAHRI reference: 217270585 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4027452 → |
NCHC48CT5****+TDR+ furnace: NF96U110V5C***Cold climate designationAHRI reference: 217270638 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4027471 → |
NCHC48CT5****+TDR+ furnace: NF98U090M5C***Cold climate designationAHRI reference: 217270588 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4027474 → |
NCHC48CT5****+TDR+ furnace: NF97U090V5C***Cold climate designationAHRI reference: 217270590 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4027476 → |
NCHC60DT5****+TDR+ furnace: NF80U135S5D***Cold climate designationAHRI reference: 217270593 | 16.00 | 8.10 | 40500 | 1.85 | EPA 4027479 → |
NCUC5060CT5****+TDR+ furnace: NF80U090S5C***Cold climate designationAHRI reference: 217270594 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4027480 → |
NCUC5060CT5****+TDR+ furnace: NF80U110S5C***Cold climate designationAHRI reference: 217270595 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4027481 → |
NCUC5060CT5****+TDR+ furnace: NF98U110M5C***Cold climate designationAHRI reference: 217270604 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4027486 → |
NCUC5060CT5****+TDR+ furnace: NF97U110V5C***Cold climate designationAHRI reference: 217270607 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4027489 → |
NCDC5060CT5****+TDR+ furnace: NF97D110M5C***Cold climate designationAHRI reference: 217270610 | 16.00 | 8.50 | 41000 | 1.85 | EPA 4027492 → |
NCDC5060CT5****+TDR+ furnace: NF97D090V5C***Cold climate designationAHRI reference: 217270611 | 16.00 | 8.50 | 41000 | 1.90 | EPA 4027493 → |
NCDC5060CT5****+TDR+ furnace: NF97D110V5C***Cold climate designationAHRI reference: 217270612 | 16.00 | 8.50 | 41000 | 1.90 | EPA 4027494 → |
NCDC42BT5****+TDR+ furnace: NF96D070V4B***Cold climate designationAHRI reference: 217270639 | 16.00 | 9.00 | 40000 | 1.85 | EPA 4027504 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →