Haier / AIR-SOURCE HEAT PUMP

1U60T3PE*HE

Connect · source records, page 10

191 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity42,500–55,500BTU/h

Each efficiency range summarizes published EPA records for 1U60T3PE*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18191 / 191
EER2 · BTU/Wh9.6–11.7191 / 191
HSPF2 · BTU/Wh8.1–9.5191 / 191
Cooling capacity · BTU/h42,500–55,500191 / 191
Heating capacity at 47°F / 8.3°C · BTU/h47,500–56,000191 / 191
Heating capacity at 17°F / −8.3°C · BTU/h38,000–45,000191 / 191
Heating capacity at 5°F / −15°C · BTU/h39,000–43,000191 / 191
COP at 5°F / −15°C1.75–1.95191 / 191
Equipment / loop typeHP - Split System191 / 191
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)191 / 191
Compressor stagingContinuously variable191 / 191
Connected capabilityNo191 / 191

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC48CT5****+TDR+ furnace: NF95X100S5C***Cold climate designationAHRI reference: 21727058915.608.50400001.80EPA 4027475
NCUC5060CT5****+TDR+ furnace: NF98U090M5C***Cold climate designationAHRI reference: 21727060515.608.10415001.75EPA 4027487
NCUC48CT5****+TDRCold climate designationAHRI reference: 21727016315.208.50390001.75EPA 4027520
NCUC60CT5****+TDRCold climate designationAHRI reference: 21727016415.208.50400001.75EPA 4027521
NCHC42BT5****+TDRCold climate designationAHRI reference: 21727021015.208.50395001.85EPA 4027558
NCUC49CT5****+TDRCold climate designationAHRI reference: 21727020915.208.10395001.80EPA 4027559
NCUC60DT5****+TDRCold climate designationAHRI reference: 21727021615.208.10415001.80EPA 4027560
NCDC48CT5****+TDRCold climate designationAHRI reference: 21727021515.208.50395001.85EPA 4027561
NCDC42BT5****+TDRCold climate designationAHRI reference: 21727021415.208.50395001.85EPA 4027562
NCDC60DT5****+TDRCold climate designationAHRI reference: 21727022015.208.50415001.95EPA 4027563
NCDC60CT5****+TDRCold climate designationAHRI reference: 21727021915.208.50415001.95EPA 4027564

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →