1U36T3PC*HE
Connect · source records, page 6
177 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 1U36T3PC*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 177 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 177 / 177 |
| EER2 · BTU/Wh | 10–12 | 177 / 177 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 177 / 177 |
| Cooling capacity · BTU/h | 32,200–36,000 | 177 / 177 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,000 | 177 / 177 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,400 | 177 / 177 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,200–30,000 | 177 / 177 |
| COP at 5°F / −15°C | 1.8–1.95 | 177 / 177 |
| Equipment / loop type | HP - Split System | 177 / 177 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 177 / 177 |
| Compressor staging | Continuously variable | 177 / 177 |
| Connected capability | No | 177 / 177 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC30BT5****+TDR+ furnace: NF96U070V3B***Cold climate designationAHRI reference: 217270622 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4027455 → |
NCHC30BT5****+TDR+ furnace: NF96U045V3B***Cold climate designationAHRI reference: 217270625 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4027458 → |
NCHC36BT5****+TDR+ furnace: NF96U045V3B***Cold climate designationAHRI reference: 217270627 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4027460 → |
NCUC30BT5****+TDR+ furnace: NF97U070V3B***Cold climate designationAHRI reference: 217270247 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4027583 → |
NCHC30BT5****+TDR+ furnace: NF97U045V3B***Cold climate designationAHRI reference: 217270254 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4027591 → |
NCHC36BT5****+TDR+ furnace: NF97U045V3B***Cold climate designationAHRI reference: 217270258 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4027594 → |
NCUC30AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 217270378 | 17.30 | 8.50 | 28600 | 1.85 | EPA 4027705 → |
NCUC30AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 217270379 | 17.30 | 8.50 | 28600 | 1.85 | EPA 4027706 → |
NCUC36BT5****+TDR+ furnace: NF80D090S4B***Cold climate designationAHRI reference: 217270419 | 17.30 | 8.50 | 28200 | 1.90 | EPA 4027746 → |
NCDC3036BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 217270470 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4027797 → |
NCDC42BT5****+TDR+ furnace: NF80D090T4B***Cold climate designationAHRI reference: 217270478 | 17.30 | 8.50 | 28200 | 1.90 | EPA 4027805 → |
NCU[C,U]36CT5****+TDR+ furnace: NF96U090S4C***Cold climate designationAHRI reference: 217729289 | 17.30 | 8.50 | 28600 | 1.85 | EPA 4498362 → |
NCDC36BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 217903502 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4515661 → |
NCUC30BT5****+TDR+ furnace: NF96U070S3B***Cold climate designationAHRI reference: 217270390 | 17.25 | 8.50 | 28600 | 1.80 | EPA 4027717 → |
NCU[C,U]36CT5****+TDR+ furnace: NF80U110T3BF***Cold climate designationAHRI reference: 217729285 | 17.25 | 8.50 | 28600 | 1.85 | EPA 4498358 → |
NCU[C,U]36CT5****+TDR+ furnace: NF93U110S4CF***Cold climate designationAHRI reference: 217729291 | 17.25 | 8.50 | 28400 | 1.85 | EPA 4498364 → |
NCDC42BT5****+TDR+ furnace: NF96D070V4B***Cold climate designationAHRI reference: 217270631 | 17.20 | 8.50 | 28600 | 1.90 | EPA 4027464 → |
NCDC42BT5****+TDR+ furnace: NF97D070V4B***Cold climate designationAHRI reference: 217270262 | 17.20 | 8.50 | 28600 | 1.90 | EPA 4027598 → |
NCHC30BT5****+TDR+ furnace: NF80D090S4B***Cold climate designationAHRI reference: 217270442 | 17.20 | 8.50 | 28400 | 1.85 | EPA 4027769 → |
NCHC36CT5****+TDR+ furnace: NF96U090S4C***Cold climate designationAHRI reference: 217270469 | 17.20 | 9.00 | 28200 | 1.90 | EPA 4027796 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →