Haier / AIR-SOURCE HEAT PUMP

1U36T3PC*HE

Connect · source records, page 6

177 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,200–36,000BTU/h

Each efficiency range summarizes published EPA records for 1U36T3PC*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 177 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19177 / 177
EER2 · BTU/Wh10–12177 / 177
HSPF2 · BTU/Wh8.1–9.5177 / 177
Cooling capacity · BTU/h32,200–36,000177 / 177
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,000177 / 177
Heating capacity at 17°F / −8.3°C · BTU/h27,000–29,400177 / 177
Heating capacity at 5°F / −15°C · BTU/h28,200–30,000177 / 177
COP at 5°F / −15°C1.8–1.95177 / 177
Equipment / loop typeHP - Split System177 / 177
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)177 / 177
Compressor stagingContinuously variable177 / 177
Connected capabilityNo177 / 177

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30BT5****+TDR+ furnace: NF96U070V3B***Cold climate designationAHRI reference: 21727062217.308.50284001.85EPA 4027455
NCHC30BT5****+TDR+ furnace: NF96U045V3B***Cold climate designationAHRI reference: 21727062517.308.50284001.85EPA 4027458
NCHC36BT5****+TDR+ furnace: NF96U045V3B***Cold climate designationAHRI reference: 21727062717.308.50284001.85EPA 4027460
NCUC30BT5****+TDR+ furnace: NF97U070V3B***Cold climate designationAHRI reference: 21727024717.308.50284001.85EPA 4027583
NCHC30BT5****+TDR+ furnace: NF97U045V3B***Cold climate designationAHRI reference: 21727025417.308.50284001.85EPA 4027591
NCHC36BT5****+TDR+ furnace: NF97U045V3B***Cold climate designationAHRI reference: 21727025817.308.50284001.85EPA 4027594
NCUC30AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 21727037817.308.50286001.85EPA 4027705
NCUC30AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 21727037917.308.50286001.85EPA 4027706
NCUC36BT5****+TDR+ furnace: NF80D090S4B***Cold climate designationAHRI reference: 21727041917.308.50282001.90EPA 4027746
NCDC3036BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 21727047017.308.50284001.85EPA 4027797
NCDC42BT5****+TDR+ furnace: NF80D090T4B***Cold climate designationAHRI reference: 21727047817.308.50282001.90EPA 4027805
NCU[C,U]36CT5****+TDR+ furnace: NF96U090S4C***Cold climate designationAHRI reference: 21772928917.308.50286001.85EPA 4498362
NCDC36BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 21790350217.308.50284001.85EPA 4515661
NCUC30BT5****+TDR+ furnace: NF96U070S3B***Cold climate designationAHRI reference: 21727039017.258.50286001.80EPA 4027717
NCU[C,U]36CT5****+TDR+ furnace: NF80U110T3BF***Cold climate designationAHRI reference: 21772928517.258.50286001.85EPA 4498358
NCU[C,U]36CT5****+TDR+ furnace: NF93U110S4CF***Cold climate designationAHRI reference: 21772929117.258.50284001.85EPA 4498364
NCDC42BT5****+TDR+ furnace: NF96D070V4B***Cold climate designationAHRI reference: 21727063117.208.50286001.90EPA 4027464
NCDC42BT5****+TDR+ furnace: NF97D070V4B***Cold climate designationAHRI reference: 21727026217.208.50286001.90EPA 4027598
NCHC30BT5****+TDR+ furnace: NF80D090S4B***Cold climate designationAHRI reference: 21727044217.208.50284001.85EPA 4027769
NCHC36CT5****+TDR+ furnace: NF96U090S4C***Cold climate designationAHRI reference: 21727046917.209.00282001.90EPA 4027796

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →