1U36T3PC*HE
Connect · source records, page 2
177 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 1U36T3PC*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 177 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 177 / 177 |
| EER2 · BTU/Wh | 10–12 | 177 / 177 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 177 / 177 |
| Cooling capacity · BTU/h | 32,200–36,000 | 177 / 177 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,000 | 177 / 177 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,400 | 177 / 177 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,200–30,000 | 177 / 177 |
| COP at 5°F / −15°C | 1.8–1.95 | 177 / 177 |
| Equipment / loop type | HP - Split System | 177 / 177 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 177 / 177 |
| Compressor staging | Continuously variable | 177 / 177 |
| Connected capability | No | 177 / 177 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NAM42E1TA5****Cold climate designationAHRI reference: 217270176 | 18.00 | 9.00 | 30000 | 1.90 | EPA 4027530 → |
NCHC36CT5****+TDR+ furnace: NF97U090V3C***Cold climate designationAHRI reference: 217270260 | 18.00 | 9.00 | 28400 | 1.90 | EPA 4027596 → |
NCUC36AT5****+TDR+ furnace: NF80U045S3A***Cold climate designationAHRI reference: 217270405 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4027732 → |
NCUC36AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 217270406 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4027733 → |
NAM42E3TA5****Cold climate designationAHRI reference: 217270224 | 18.00 | 9.40 | 29000 | 1.90 | EPA 4029072 → |
NCUC36AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217270399 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4027726 → |
NCHC30AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217270422 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4027749 → |
NCHC30AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217270423 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4027750 → |
NCHC30AT5****+TDR+ furnace: NF80U070S3A***Cold climate designationAHRI reference: 217270427 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4027755 → |
NCHC30BT5****+TDR+ furnace: NF80U070S3B***Cold climate designationAHRI reference: 217270430 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4027757 → |
NCHC30BT5****+TDR+ furnace: NF80L070S3B***Cold climate designationAHRI reference: 217270431 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4027758 → |
NCHC36BT5****+TDR+ furnace: NF80U070S3B***Cold climate designationAHRI reference: 217270453 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4027780 → |
NCHC36BT5****+TDR+ furnace: NF80L070S3B***Cold climate designationAHRI reference: 217270454 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4027781 → |
NCHC36CT5****+TDR+ furnace: NF98U090M4C***Cold climate designationAHRI reference: 217270467 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4027794 → |
NCHC36CT5****+TDR+ furnace: NF97X080V4C***Cold climate designationAHRI reference: 217270261 | 17.90 | 9.00 | 28400 | 1.90 | EPA 4027597 → |
NCUC36AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217270400 | 17.90 | 8.50 | 28400 | 1.85 | EPA 4027727 → |
NCUC36AT5****+TDR+ furnace: NF80U070S3A***Cold climate designationAHRI reference: 217270404 | 17.90 | 8.50 | 28400 | 1.85 | EPA 4027731 → |
NCDC42BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 217270475 | 17.90 | 9.00 | 28200 | 1.90 | EPA 4027802 → |
NCDC42BT5****+TDR+ furnace: NF96D045S3B***Cold climate designationAHRI reference: 217270477 | 17.85 | 9.00 | 28200 | 1.90 | EPA 4027804 → |
NCU[C,U]36CT5****+TDR+ furnace: NF97U110V4CF***Cold climate designationAHRI reference: 217729281 | 17.85 | 8.50 | 28400 | 1.85 | EPA 4498354 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →