1U24T3PS*HE
Connect · source records, page 3
119 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 1U24T3PS*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 119 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 119 / 119 |
| EER2 · BTU/Wh | 11–12.3 | 119 / 119 |
| HSPF2 · BTU/Wh | 8.5–10 | 119 / 119 |
| Cooling capacity · BTU/h | 23,200–24,000 | 119 / 119 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,000 | 119 / 119 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 119 / 119 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 119 / 119 |
| COP at 5°F / −15°C | 1.75–1.85 | 119 / 119 |
| Equipment / loop type | HP - Split System | 119 / 119 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 119 / 119 |
| Compressor staging | Continuously variable | 119 / 119 |
| Connected capability | No | 119 / 119 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC36AT5****+TDR+ furnace: NF80X060V3A***Cold climate designationAHRI reference: 217270309 | 17.25 | 9.00 | 20600 | 1.85 | EPA 4027646 → |
NCHC30AT5****+TDR+ furnace: NF80U070V3A***Cold climate designationAHRI reference: 217270352 | 17.20 | 9.40 | 20800 | 1.85 | EPA 4027679 → |
NCUC30BT5****+TDR+ furnace: NF96U070V3B***Cold climate designationAHRI reference: 217270614 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4027496 → |
NCUC30BT5****+TDR+ furnace: NF97U070V3B***Cold climate designationAHRI reference: 217270231 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4027568 → |
NCUC30BT5****+TDR+ furnace: NF98U070M3B***Cold climate designationAHRI reference: 217270303 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4027640 → |
NCUC36AT5****+TDR+ furnace: NF80U045S3A***Cold climate designationAHRI reference: 217270316 | 17.15 | 9.00 | 20800 | 1.85 | EPA 4027653 → |
NCUC36AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 217270317 | 17.15 | 9.00 | 20800 | 1.85 | EPA 4027654 → |
NCHC30AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 217270356 | 17.15 | 9.40 | 20600 | 1.85 | EPA 4027683 → |
NCHC30AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 217270357 | 17.15 | 9.40 | 20600 | 1.85 | EPA 4027684 → |
NCDC24BT5****+TDR+ furnace: NF97D070M3B***Cold climate designationAHRI reference: 217270372 | 17.15 | 9.40 | 20800 | 1.80 | EPA 4027699 → |
NCUC36AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 217270312 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4027647 → |
NCUC36AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 217270313 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4027650 → |
NCUC30AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217270293 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4027629 → |
NCUC30AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217270294 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4027630 → |
NCUC36AT5****+TDR+ furnace: NF80U070V3A***Cold climate designationAHRI reference: 217270308 | 17.05 | 9.00 | 20800 | 1.85 | EPA 4027645 → |
NAM24V2TA5****Cold climate designationAHRI reference: 217270171 | 17.00 | 9.40 | 23200 | 1.80 | EPA 4027526 → |
NCUC30BT5****+TDR+ furnace: NF97X060V3B***Cold climate designationAHRI reference: 217270229 | 17.00 | 9.00 | 20800 | 1.80 | EPA 4027567 → |
NAM24E3TA5****Cold climate designationAHRI reference: 217270221 | 17.00 | 9.50 | 22600 | 1.85 | EPA 4029070 → |
NCUC30BT5****+TDR+ furnace: NF96U045V3B***Cold climate designationAHRI reference: 217270613 | 16.95 | 9.00 | 20800 | 1.80 | EPA 4027495 → |
NCUC30BT5****+TDR+ furnace: NF97U045V3B***Cold climate designationAHRI reference: 217270230 | 16.95 | 9.00 | 20800 | 1.80 | EPA 4027566 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →