Guardian / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 4

133 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity33,000–35,800BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 133 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17133 / 133
EER2 · BTU/Wh11–12133 / 133
HSPF2 · BTU/Wh8–8.5133 / 133
Cooling capacity · BTU/h33,000–35,800133 / 133
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200133 / 133
Heating capacity at 17°F / −8.3°C · BTU/h22,200–23,800133 / 133
Heating capacity at 5°F / −15°C · BTU/h18,000–19,800133 / 133
COP at 5°F / −15°C2–2.48133 / 133
Equipment / loop typeHP - Split System133 / 133
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)133 / 133
Compressor stagingTwo-stage133 / 133
Connected capabilityNo133 / 133

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5CFS1+JME12C2SN1AHRI reference: 21701847716.008.50190002.46EPA 4013614 →
CTM48C5CFS1+ furnace: RL18080C20MPS1AHRI reference: 21701847916.008.50193002.44EPA 4013615 →
CTM36C5CDS1+ furnace: RL18080C20MPS1AHRI reference: 21701848016.008.10187002.34EPA 4013616 →
CTM36C5CDS1+ furnace: RL18080C16MPS1AHRI reference: 21701848116.008.10188002.34EPA 4013617 →
CTM48C5CFS1+ furnace: RL18100C16MPS1AHRI reference: 21701848316.008.50195002.42EPA 4013618 →
CTM36C5CDS1+ furnace: RL18100C16MPS1AHRI reference: 21701848416.008.10186002.34EPA 4013619 →
CTM36C5CDS1+ furnace: RL18120C16MPS1AHRI reference: 21701848516.008.10185002.36EPA 4013620 →
CTM48C5CFS1+ furnace: RL18120C16MPS1AHRI reference: 21701848616.008.50190002.46EPA 4013621 →
CTM48C5CFS1+ furnace: RG19080C16MPS1AHRI reference: 21701848916.008.10191002.42EPA 4013622 →
CTM36C5CDS1+ furnace: RG19080C16MPS1AHRI reference: 21701849016.008.10191002.28EPA 4013623 →
CTM36C5CDS1+ furnace: RL18120C20MPS1AHRI reference: 21701849116.008.10188002.32EPA 4013624 →
CTM36C5CDS1+ furnace: RG19080C20MPS1AHRI reference: 21701849216.008.10189002.32EPA 4013625 →
JHE36C5CD2SS1AHRI reference: 21702033116.008.10185002.36EPA 4013742 →
JHE42C5CF2SS1AHRI reference: 21702033316.008.10190002.46EPA 4013743 →
JHE36B5CD2SS1AHRI reference: 21701675216.008.00180002.00EPA 4498120 →
JHE36B5CD2SS2AHRI reference: 21845721316.008.00180002.00EPA 4622470 →
JHE36C5CD2SS2AHRI reference: 21845720716.008.10185002.36EPA 4622476 →
CTF36C5CDS2+ furnace: RL18120C16MPS1AHRI reference: 21852773916.008.10185002.36EPA 4646447 →
CTF36C5CDS2+ furnace: RG19080C16MPS1AHRI reference: 21852771716.008.10196002.26EPA 4646469 →
CTF36C5CDS2+ furnace: RL18080C20MPS1AHRI reference: 21852770716.008.10187002.34EPA 4646479 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.