XH636E2S11
LX SERIES
133 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 133 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 133 / 133 |
| EER2 · BTU/Wh | 11–12 | 133 / 133 |
| HSPF2 · BTU/Wh | 8–8.5 | 133 / 133 |
| Cooling capacity · BTU/h | 33,000–35,800 | 133 / 133 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 133 / 133 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,200–23,800 | 133 / 133 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,000–19,800 | 133 / 133 |
| COP at 5°F / −15°C | 2–2.48 | 133 / 133 |
| Equipment / loop type | HP - Split System | 133 / 133 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 133 / 133 |
| Compressor staging | Two-stage | 133 / 133 |
| Connected capability | No | 133 / 133 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF48C5CFS1+JMET12CS2N1AHRI reference: 217017601 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4013309 → |
CTU48C5XFS1+JMET12CS2N1+TXVAHRI reference: 217017602 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4013310 → |
CTF48C5CFS1+JMET16CS2N1AHRI reference: 217017610 | 17.00 | 8.10 | 19000 | 2.44 | EPA 4013316 → |
CTU48C5XFS1+JMET16CS2N1+TXVAHRI reference: 217017611 | 17.00 | 8.10 | 19000 | 2.44 | EPA 4013317 → |
CTF48C5CFS1+JME16C2SN1AHRI reference: 217017613 | 17.00 | 8.10 | 18900 | 2.46 | EPA 4013318 → |
CTU48C5XFS1+JME16C2SN1+TXVAHRI reference: 217017614 | 17.00 | 8.10 | 18900 | 2.46 | EPA 4013319 → |
CTF48D5CFS1+JME18D2SN1AHRI reference: 217017615 | 17.00 | 8.50 | 19000 | 2.48 | EPA 4013321 → |
CTF48C5CFS1+JME12C2SN1AHRI reference: 217017622 | 17.00 | 8.50 | 19000 | 2.46 | EPA 4013326 → |
CTU48C5XFS1+JME12C2SN1+TXVAHRI reference: 217017623 | 17.00 | 8.50 | 19000 | 2.46 | EPA 4013327 → |
CTF48C5CFS1+ furnace: RL18080C20MPS1AHRI reference: 217017630 | 17.00 | 8.50 | 19300 | 2.42 | EPA 4013334 → |
CTU48C5XFS1+TXV+ furnace: RL18080C20MPS1AHRI reference: 217017631 | 17.00 | 8.50 | 19300 | 2.42 | EPA 4013335 → |
CTF48C5CFS1+ furnace: RL18100C16MPS1AHRI reference: 217017633 | 17.00 | 8.50 | 19500 | 2.42 | EPA 4013337 → |
CTU48C5XFS1+TXV+ furnace: RL18100C16MPS1AHRI reference: 217017634 | 17.00 | 8.50 | 19500 | 2.42 | EPA 4013338 → |
CTF48C5CFS1+ furnace: RL18120C16MPS1AHRI reference: 217017636 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4013339 → |
CTU48C5XFS1+TXV+ furnace: RL18120C16MPS1AHRI reference: 217017637 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4013341 → |
CTU48C5XFS1+TXV+ furnace: RG19080C20MPS1AHRI reference: 217017644 | 17.00 | 8.10 | 19400 | 2.40 | EPA 4013346 → |
CTF48C5CFS1+ furnace: RG19080C20MPS1AHRI reference: 217017645 | 17.00 | 8.10 | 19400 | 2.40 | EPA 4013347 → |
CTF48C5CFS1+ furnace: RG19080C16MPS1AHRI reference: 217017647 | 17.00 | 8.10 | 18900 | 2.40 | EPA 4013349 → |
CTU48C5XFS1+TXV+ furnace: RG19080C16MPS1AHRI reference: 217017648 | 17.00 | 8.10 | 18900 | 2.40 | EPA 4013350 → |
CTU48C5XFS2+TXV+ furnace: RL18100C16MPS1AHRI reference: 218527933 | 17.00 | 8.50 | 19500 | 2.42 | EPA 4646259 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →