RHP15060B21
LX SERIES
19 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RHP15060B21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 19 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 19 / 19 |
| EER2 · BTU/Wh | 11–12 | 19 / 19 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 19 / 19 |
| Cooling capacity · BTU/h | 53,000–56,500 | 19 / 19 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 54,500–59,500 | 19 / 19 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,400–38,500 | 19 / 19 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,600–32,800 | 19 / 19 |
| COP at 5°F / −15°C | 2.22–2.46 | 19 / 19 |
| Equipment / loop type | HP - Split System | 19 / 19 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 19 / 19 |
| Compressor staging | Two-stage | 19 / 19 |
| Connected capability | No | 19 / 19 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
JHETD60JBCS2N1AHRI reference: 212541120 | 16.00 | 8.10 | 30800 | 2.24 | EPA 2838598 → |
JHETD60HBCS2N1AHRI reference: 212541145 | 16.00 | 8.10 | 30600 | 2.26 | EPA 2838604 → |
JHVTD60JBCC2N1AHRI reference: 212582168 | 16.00 | 8.10 | 30600 | 2.22 | EPA 2838626 → |
JHVTD60HBCC2N1AHRI reference: 212582178 | 16.00 | 8.10 | 30600 | 2.28 | EPA 2838632 → |
XAHD60HBCN1+ furnace: RL18120C16MPS1AHRI reference: 212478715 | 15.20 | 7.80 | 32600 | 2.34 | EPA 2476941 → |
XAFC60HBCN1+ furnace: RL18080C16MPS1AHRI reference: 212480008 | 15.20 | 7.80 | 31000 | 2.34 | EPA 2482182 → |
XAFD60HBCN1+ furnace: RL18080C16MPS1AHRI reference: 212489300 | 15.20 | 7.80 | 31000 | 2.34 | EPA 2482425 → |
XAHC60HBCN1+ furnace: RL18080C16MPS1AHRI reference: 212476619 | 15.20 | 7.80 | 32400 | 2.34 | EPA 2483507 → |
XAHD60HBCN1+ furnace: RL18130D20MPS1AHRI reference: 212478698 | 15.20 | 7.80 | 32600 | 2.34 | EPA 2483572 → |
XAHC60HBCN1+ furnace: RL18100C20MPS1AHRI reference: 212486012 | 15.20 | 7.80 | 32800 | 2.34 | EPA 2485081 → |
JHETC60HBCS2N1AHRI reference: 212541165 | 15.20 | 7.80 | 30600 | 2.22 | EPA 2838613 → |
JHVTC60HBCC2N1AHRI reference: 212582187 | 15.20 | 8.10 | 30800 | 2.26 | EPA 2838637 → |
XAFC60HBCN1+JME16C2SN1AHRI reference: 214799856 | 15.20 | 8.10 | 31600 | 2.36 | EPA 3559627 → |
XAFD60HBCN1+JME18D2SN1AHRI reference: 214799863 | 15.20 | 8.10 | 31800 | 2.40 | EPA 3559634 → |
XAFD60JBCN1+JME18D2SN1AHRI reference: 214799897 | 15.20 | 8.10 | 31200 | 2.46 | EPA 3559646 → |
XAHD60JBCN1+JME18D2SN1AHRI reference: 214799909 | 15.20 | 8.10 | 30800 | 2.42 | EPA 3559658 → |
XAFD60HBCN1+ furnace: RG19120D20MPS1AHRI reference: 214647935 | 15.20 | 7.80 | 31600 | 2.34 | EPA 3721875 → |
XAHD60JBCN1+ furnace: RG19120D20MPS1AHRI reference: 214647942 | 15.20 | 8.10 | 31400 | 2.32 | EPA 3721877 → |
XAFD60JBCN1+ furnace: RG19120D20MPS1AHRI reference: 214647949 | 15.20 | 8.10 | 31800 | 2.42 | EPA 4049206 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →