GREE / AIR-SOURCE HEAT PUMP

SAP09HP230V1R32AO

360° air discharge cassette unit · Airy · Console · Ducted · Floor ceiling · One-way air discharge cassette unit

6 published source records · source checked Sep 21, 2026

SEER2 range22.3–30BTU/Wh
HSPF2 range9.5–11.2BTU/Wh
Cooling capacity9,100BTU/h

Each efficiency range summarizes published EPA records for SAP09HP230V1R32AO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 6 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh22.3–306 / 6
EER2 · BTU/Wh13.65–16.86 / 6
HSPF2 · BTU/Wh9.5–11.26 / 6
Cooling capacity · BTU/h9,1006 / 6
Heating capacity at 47°F / 8.3°C · BTU/h10,500–10,6006 / 6
Heating capacity at 17°F / −8.3°C · BTU/h8,900–12,0006 / 6
Heating capacity at 5°F / −15°C · BTU/h8,500–11,5006 / 6
COP at 5°F / −15°C1.75–2.116 / 6
Equipment / loop typeHP - Mini or Multi Split6 / 6
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)6 / 6
Compressor stagingContinuously variable6 / 6
Connected capabilityNo6 / 6

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
SAP09HP230V1R32AHCold climate designationAHRI reference: 21480244430.0011.20115002.11EPA 3544188
FLR09HP230V1R32AHCold climate designationAHRI reference: 21541554925.509.80105001.90EPA 3624620
CAS09HP230V1R32AHCold climate designationAHRI reference: 21541554824.509.5085001.84EPA 3624619
CON09HP230V1R32AHCold climate designationAHRI reference: 21541555023.309.50100001.75EPA 3624621
OWC09HP230V1R32AHCold climate designationAHRI reference: 21541555122.509.5090001.75EPA 3624622
DUC09HP230V1R32AHCold climate designationAHRI reference: 21541554722.309.5092001.80EPA 3624618

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →