SEER2 range22–26BTU/Wh
HSPF2 range9.2–10.4BTU/Wh
Cooling capacity9,100BTU/h

Each efficiency range summarizes published EPA records for GWH09AGCXD-D6DNA4D/O. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 8 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh22–268 / 8
EER2 · BTU/Wh13.1–158 / 8
HSPF2 · BTU/Wh9.2–10.48 / 8
Cooling capacity · BTU/h9,1008 / 8
Heating capacity at 47°F / 8.3°C · BTU/h10,5008 / 8
Heating capacity at 17°F / −8.3°C · BTU/h8,800–11,0008 / 8
Heating capacity at 5°F / −15°C · BTU/h7,600–10,0008 / 8
COP at 5°F / −15°C1.75–2.158 / 8
Equipment / loop typeHP - Mini or Multi Split8 / 8
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)8 / 8
Compressor stagingContinuously variable8 / 8
Connected capabilityNo8 / 8

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
GWH09AGCXD-D6DN***/ICold climate designationAHRI reference: 21539207326.0010.4095001.88EPA 3621238
GWH09AUCXD-D6DN***/ICold climate designationAHRI reference: 21603243526.0010.4095001.88EPA 3723378
GWH09AUCXD-D6DNA2D/I**Cold climate designationAHRI reference: 21842626526.0010.4095001.88EPA 4610455
GTH(09)CA-D6DN***/ICold climate designationAHRI reference: 21661820825.009.60100001.95EPA 3893634
GKH(09)EB-D6DN***/ICold climate designationAHRI reference: 21661820624.009.2076001.94EPA 3942904
GEH(09)AA-D6DN***/ICold climate designationAHRI reference: 21661820923.009.4087001.75EPA 3893636
GKH(09)DA-D6DN***/ICold climate designationAHRI reference: 21661820722.009.5094001.97EPA 3893632
GFH(09)DA-D6DN***/ICold climate designationAHRI reference: 21661821022.009.2095002.15EPA 3893635

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.