W5H8T48*K*AAA*
2-STAGE 18 SEER HP
106 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for W5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 106 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 106 / 106 |
| EER2 · BTU/Wh | 11.7–13.5 | 106 / 106 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 106 / 106 |
| Cooling capacity · BTU/h | 46,000–50,000 | 106 / 106 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,000 | 106 / 106 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,400 | 106 / 106 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,200 | 106 / 106 |
| COP at 5°F / −15°C | 2.1–2.32 | 106 / 106 |
| Equipment / loop type | HP - Split System | 106 / 106 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 106 / 106 |
| Compressor staging | Two-stage | 106 / 106 |
| Connected capability | No | 106 / 106 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
WCGL605*D*AHRI reference: 215560728 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982818 → |
QFVA5D6021X*AHRI reference: 218695454 | 18.00 | 8.50 | 25800 | 2.32 | EPA 4683373 → |
W5VM49M21XA*+ furnace: WFEU080C060B*AHRI reference: 215623325 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3947649 → |
W5VM60M21XA*+ furnace: WFEU080C060B*AHRI reference: 215623723 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948285 → |
W5VC49M24XA*+ furnace: WFEU080C060B*AHRI reference: 215624481 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3948722 → |
W5VC61M21XA*+ furnace: WFEU060B048B*AHRI reference: 215625053 | 17.50 | 8.10 | 25000 | 2.12 | EPA 3949263 → |
W5VC61M21XA*+ furnace: WFEU080C060B*AHRI reference: 215625072 | 17.50 | 8.50 | 24400 | 2.30 | EPA 3949284 → |
W5VC61M21XA*+ furnace: WFEU100C060B*AHRI reference: 215625091 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949302 → |
W5VC61M21XA*+ furnace: WFET110C066A*AHRI reference: 215625167 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3949493 → |
W5VC61M24XA*+ furnace: WFET110C066A*AHRI reference: 215625512 | 17.50 | 8.50 | 24800 | 2.28 | EPA 3949846 → |
QFVA5D4821X*AHRI reference: 218695437 | 17.50 | 8.10 | 25400 | 2.18 | EPA 4683390 → |
W5VM48M21XA*+ furnace: WFEU080C060B*AHRI reference: 215622968 | 17.00 | 8.10 | 24000 | 2.14 | EPA 3947373 → |
W5VM49M21XA*+ furnace: WFEU060B048B*AHRI reference: 215623306 | 17.00 | 8.10 | 25000 | 2.12 | EPA 3947632 → |
W5VM49M21XA*+ furnace: WFEU100C060B*AHRI reference: 215623344 | 17.00 | 8.10 | 24800 | 2.10 | EPA 3947667 → |
W5VM49M21XA*+ furnace: WFET110C066A*AHRI reference: 215623420 | 17.00 | 8.10 | 24800 | 2.12 | EPA 3947743 → |
W5VM49M21XA*+ furnace: WFSU100C060B*AHRI reference: 215623554 | 17.00 | 8.10 | 25200 | 2.10 | EPA 3947864 → |
W5VC48M21XA*+ furnace: WFEU080C060B*AHRI reference: 215624108 | 17.00 | 8.10 | 24000 | 2.14 | EPA 3948103 → |
W5VM60M21XA*+ furnace: WFEU060B048B*AHRI reference: 215623704 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3948263 → |
W5VM60M21XA*+ furnace: WFEU100C060B*AHRI reference: 215623742 | 17.00 | 8.10 | 24800 | 2.10 | EPA 3948311 → |
W5VM60M21XA*+ furnace: WFET110C066A*AHRI reference: 215623818 | 17.00 | 8.10 | 24400 | 2.14 | EPA 3948379 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →