Grandaire / AIR-SOURCE HEAT PUMP

W5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 5

124 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for W5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 124 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5124 / 124
EER2 · BTU/Wh11.5–14124 / 124
HSPF2 · BTU/Wh7.8–8.1124 / 124
Cooling capacity · BTU/h22,200–25,000124 / 124
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,000124 / 124
Heating capacity at 17°F / −8.3°C · BTU/h14,100–14,900124 / 124
Heating capacity at 5°F / −15°C · BTU/h10,700–11,400124 / 124
COP at 5°F / −15°C1.9–2.16124 / 124
Equipment / loop typeHP - Split System124 / 124
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)124 / 124
Compressor stagingTwo-stage124 / 124
Connected capabilityNo124 / 124

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
W5SH30M12XA*+ furnace: WFSU080C060B*AHRI reference: 21565126916.508.00112002.06EPA 3963686 →
W5SH30M12XA*+ furnace: WFSU100C060B*AHRI reference: 21565129516.508.00111002.08EPA 3963708 →
W5SH36M12XA*+ furnace: WFET045A036A*AHRI reference: 21565221016.507.80109001.96EPA 3964113 →
W5SH36M12XA*+ furnace: WFET070A036A*AHRI reference: 21565222516.507.80109001.96EPA 3964116 →
W5SH36M12XA*+ furnace: WFET090B048A*AHRI reference: 21565226216.507.80110001.96EPA 3964145 →
W5SH30M12XA*+ furnace: WFST100C060A*AHRI reference: 21565163316.507.80110002.08EPA 3964268 →
W5SH36M12XA*+ furnace: WFEU040B036B*AHRI reference: 21565193116.507.80110002.08EPA 3964724 →
W5SH36M12XA*+ furnace: WFEU060B048B*AHRI reference: 21565195916.507.80109002.10EPA 3964745 →
W5SH36M12XA*+ furnace: WFST060B048A*AHRI reference: 21565302616.507.80110001.96EPA 3965152 →
W5SH36M12XA*+ furnace: WFST100C060A*AHRI reference: 21565311116.507.80110002.08EPA 3965180 →
W5SH36M12XA*+ furnace: WFSU080C060B*AHRI reference: 21565275016.507.80110002.08EPA 3965632 →
W5A*24M17XA*+ furnace: WFJT060B048A*AHRI reference: 21572038916.508.10110002.05EPA 3980196 →
W5A*24M17XA*+ furnace: WFJT080B048A*AHRI reference: 21572040716.508.00110002.04EPA 3980224 →
W5A*30M17XA*+ furnace: WFJT060B048A*AHRI reference: 21572057316.508.10110002.10EPA 3980939 →
W5A*25M17XA*+ furnace: WFJT040A030A*AHRI reference: 21799170516.508.00113002.06EPA 4566308 →
W5A*37M17XA*+ furnace: WFJT040A030A*AHRI reference: 21799178516.508.00114002.04EPA 4566361 →
W5A*30M14XA*+ furnace: WFST040A030A*AHRI reference: 21564535316.008.00112002.00EPA 3958412 →
W5A*30M17XA*+ furnace: WFST040A030A*AHRI reference: 21564600016.008.00112002.00EPA 3958994 →
W5A*36M17XA*+ furnace: WFST040A030A*AHRI reference: 21564678516.008.00112002.00EPA 3959503 →
W5SH24M12XA*+ furnace: WFEU100C060B*AHRI reference: 21564908516.007.80111002.00EPA 3962074 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →